Skip to main content
Schneider Electric LC3D115P7A64

Schneider LC3D115P7A64 TeSys Deca Star-Delta Starter, Obsole

MPNLC3D115P7A64
Obsolete

Schneider Electric TeSys Deca LC3D115P7A64 pre-wired star-delta starter, 3×3P NO, AC-3 utilisation, 575 VAC, 110 kW rating.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D115P7A64 key specifications
ParameterValue
Product or component typeStar delta starter
[Ue] rated operational voltagePower circuit 10 MOhm for signalling circuit
Power pole contact composition3 x 3 NO
Poles description3 x 3P
Utilisation categoryAC-3
IP degree of protectionIP20 front face IEC 60529
Pollution degree3
Operating altitude9842.52 ft (3000 m)
RangeTeSys
CategoryUS10I1222359
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

All specifications

LC3D115P7A64 additional specifications
ParameterValue
Device short nameLC3D
Device presentationPre-wired
Protective treatmentTH IEC 60068-2-30
Contactor applicationMotor control
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Shocks contactor open6 Gn for 11 ms
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

The LC3D115P7A64 is a pre-wired TeSys Deca star-delta starter, rated for AC-3 motor-switching duty with 3×3P NO contacts, and now obsolete per Schneider. No direct replacement listed under TeSys Deca; source through surplus.

AC-3 utilisation means the contactor is designed for switching squirrel-cage motors: making and breaking currents up to several times the rated operational current. The 3×3P configuration (three NO power poles per phase) is specific to star-delta starting, reducing inrush on transition. Pollution degree 3 and IP20 front face (IEC 60529) indicate the device is intended for an industrial enclosure where conductive dust or occasional condensation may occur. TH protective treatment (IEC 60068-2-30) confirms it withstands damp heat cycles. Flame retardance V1 (UL 94) and fire resistance at 850°C (IEC 60695-2-1) are relevant for panel certification — no additional fuse or barrier needed for these aspects.

This star-delta starter is wired into MCCs or standalone panels for starting three-phase induction motors. The pre-wired format reduces field wiring time. Operating altitude is rated to 3000 m without derating; ambient operation from -40 to 60°C, with derating up to 70°C.

Sourcing & lifecycle reality

The LC3D115P7A64 is obsolete per Schneider. No direct replacement from Schneider has been recorded; verify any claimed equivalent by checking the nameplate and wiring scheme. Source through surplus or submit an RFQ for availability and lead time.

Frequently asked questions

What is the range and series of this starter?

It belongs to the TeSys range and the TeSys Deca product family.

What compliance documentation is available for this part?

The device meets IEC 60695-2-1 fire resistance (850°C), UL 94 V1 flame retardance, IP20 protection (IEC 60529), and TH protective treatment per IEC 60068-2-30. RoHS/REACH status is not listed in available data.

How should I source this obsolete starter?

Since it is no longer manufactured, sourcing is through surplus and broker channels. Submit an RFQ to confirm stock and lead time from our supply network.

MPN