Schneider Electric LC7K0601M7

Schneider LC7K0601M7 IEC Contactor

MPNLC7K0601M7
Active

Square D LC7K0601M7 6A Iec Contactor|Square D LC7K0601M7 6A Iec Contactor

$42.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC7K0601M7 key specifications
ParameterValue
Auxiliary contacts typeInstantaneous 1 NC
Product or component typeContactor
Minimum switching voltage17 V for signalling circuit
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
[Ue] rated operational voltagePower circuit Signalling circuit 10 MOhm for signalling circuit
Minimum switching current5 mA for signalling circuit
Inrush power in3 VA (at 68 °F (20 °C))
Power pole contact composition3 NO
Hold-in power consumption in3 VA (at 68 °F (20 °C))
Signalling circuit frequency<= 400 Hz
Poles description3P
Utilisation categoryAC-3 AC-3e AC-4

All specifications

LC7K0601M7 additional specifications
ParameterValue
IP degree of protectionIP2X VDE 0106
Mounting supportRail Plate
Connections - terminalsscrew clamp terminals 1 0.002...0.006 in² (1.5...4 mm²)solid screw clamp terminals 1 0.001...0.006 in² (0.75...4 mm²)flexible without cable end screw clamp terminals 1 0.0005...0.004 in² (0.34...2.5 mm²)flexible with cable end screw clamp terminals 2 0.002...0.006 in² (1.5...4 mm²)solid screw clamp terminals 2 0.001...0.006 in² (0.75...4 mm²)flexible without cable end screw clamp terminals 2 0.0005...0.002 in² (0.34...1.5 mm²)flexible with cable end
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (57 mm)
Width1.8 in (45 mm)
Height2.3 in (58 mm)
Electrical durability1.3 Mcycles 6 A AC-3 1.3 Mcycles 6 A AC-3e 0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical durability10 Mcycles
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
RangeTeSys
CategoryUS10I1222326
Operating time30...40 ms coil energisation and NO closing 30 ms coil de-energisation and NO opening
Coil technologyWithout built-in suppressor module
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Heat dissipation3 W
Device short nameLC7K
Tightening torque7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals Philips No 2 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08...11.5 lbf.in (0.8...1.3 N.m) screw clamp terminals pozidriv No 2
Device applicationControl
Non overlap distance0.02 in (0.5 mm)
Protective treatmentTC IEC 60068 TC DIN 50016
Contactor applicationMotor control
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Maximum operating rate3600 cyc/h
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ambient air temperature for storage-58...176 °F (-50...80 °C)
MPN
LC7K0601M7