Skip to main content
Schneider Electric LC7K06105D7 — Contactors

Schneider TeSys K LC7K06105D7 Contactor, 6A AC-3, 42V Coil

MPNLC7K06105D7
Active

Schneider Electric TeSys K contactor, 3-pole, AC-3 ≤440 V 6 A, 1 NO auxiliary contact, 42 V AC coil, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC7K06105D7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC7K06105D7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC7K06105D7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC7K06105D7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC7K06105D7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC7K06105D7 is a TeSys K series contactor — a compact 3-pole control device with a 42 V AC coil, rated for 6 A in AC-3 duty (≤440 V). That 6 A AC-3 rating governs motor switching: it handles 1.5 kW at 230 V, 2.2 kW at 400 V class, and up to 3 kW on 480–690 V supplies. The single NO auxiliary contact (rated 6 A at 10 MOhm for signalling circuits) is built in, no add-on block required for basic feedback.

Integration notes

The LC7K06105D7 mounts on a standard 35 mm DIN rail (snap-on), occupying 45 mm width and 58 mm height with a 57 mm depth — fits a standard 4-module wide DIN-rail footprint. The 42 V AC coil is a common control voltage for transformer-isolated panels; verify the control transformer rating accommodates the inrush.

Frequently asked questions

What motor power can this contactor switch?

At 220–230 V AC it switches 1.5 kW; at 380–415 V it switches 2.2 kW; at 440 V and above (480 V, 500–600 V, 660–690 V) it switches 3 kW. All ratings are at 50/60 Hz.

What is the closest alternative in the TeSys K family?

The closest sibling is the LC7K06105D7 itself — there is no separate pin-compatible variant with a different coil voltage. For a different coil voltage, the family uses a different order code suffix (e.g., LC7K0610B7 for 24 V AC). The 42 V AC coil version is unique to this code.

What compliance documentation is available?

The part carries UL 94 V-1 flame retardance and NF F 16-101/102 compliance. RoHS and REACH documentation are typically provided by Schneider Electric for this series; confirm with your local rep for the specific declaration files.

MPN
LC7K06105D7