Skip to main content
Schneider Electric LC7K0610D7 — Contactors

Schneider Electric LC7K0610D7 TeSys K Contactor, 6 A, 42 V A

MPNLC7K0610D7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 6 A, 1 NO aux, 42 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC7K0610D7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC7K0610D7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC7K0610D7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC7K0610D7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC7K0610D7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC7K0610D7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation3 W
Range of productTeSys K
Device short nameLC7K
Compatibility codeLC7K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider Electric LC7K0610D7 is a TeSys K contactor, 3P, rated AC-3 ≤440 V 6 A, with 1 NO auxiliary contact and a 42 V AC coil. It is now classified as obsolete by the manufacturer.

The AC-3 utilisation category means this contactor is designed for starting and stopping squirrel-cage motors — the 6 A rating at ≤440 V AC governs the motor current it can handle under those conditions. For motor power, it covers 1.5 kW at 220...230 V AC, 2.2 kW at 380...415 V AC, and up to 3 kW at 480 V AC or 660...690 V AC, all at 50/60 Hz. The 3-pole configuration with 3 NO main contacts suits standard three-phase motor control. The single NO auxiliary contact provides feedback or interlocking without an add-on block. Heat dissipation is 3 W, which is modest for panel thermal budgeting. The part carries V1 flame retardance per UL 94 and meets NF F 16-101 and NF F 16-102 requirements, relevant for rail or other fire-safety-sensitive installations.

Integration notes

The 42 V AC coil is a less common control voltage; verify the control transformer tap or supply before committing the BOM line.

Frequently asked questions

What are the key ratings of the LC7K0610D7?

It is a 3-pole contactor rated AC-3 ≤440 V 6 A, with a 42 V AC coil. Motor power capability ranges from 1.5 kW at 220...230 V AC up to 3 kW at 480 V AC or 660...690 V AC.

How can I source the LC7K0610D7 now that it is obsolete?

Sourcing is through surplus or broker channels. Submit an RFQ for a quote on available inventory; there is no standard stock or lead time from the manufacturer.

MPN
LC7K0610D7