Skip to main content
Schneider Electric LC7K09017FE7 — Contactors

TeSys K LC7K09017FE7 Contactor, 3P, 9 A AC-3, 115 VAC Coil

MPNLC7K09017FE7
Active

Schneider Electric TeSys K, 3-pole contactor, AC-3 ≤440 V 9 A, 1 NC auxiliary, 115 V AC coil, 4 kW at 480 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC7K09017FE7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC7K09017FE7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-1 AC-4 AC-3
LC7K09017FE7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC7K09017FE7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC7K09017FE7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

Part Profile

The LC7K09017FE7 is a Schneider Electric TeSys K 3-pole contactor with a 115 V AC coil and one normally closed auxiliary contact. It's rated for AC-3 duty at 9 A up to 440 V, and carries motor power ratings of 4 kW at 480 V, 500–600 V, 660–690 V, 380–415 V, and 440 V AC, plus 2.2 kW at 220–230 V AC, all at 50/60 Hz. The AC-1 and AC-4 utilisation categories are also covered, meaning it handles resistive loads and inching/jogging duty as well.

For resistive (AC-1) or plugging/inching (AC-4) duty, the rated operational current is 20 A, so the same contactor handles higher resistive loads but the AC-3 figure governs typical induction motor applications. The 4 kW across multiple voltage bands (480 V through 690 V) confirms it's sized for standard three-phase motors in that power class globally, not just one regional voltage. Heat dissipation is 3 W — low enough that multiple units can be ganged on a DIN rail without forced cooling in a standard IP20 panel. The 3-pole configuration (3 NO main poles) with a single NC auxiliary covers basic control interlocking; if you need more aux contacts, plan an add-on block.

This is a panel-mount contactor for motor control in industrial machinery, conveyors, pumps, and compressors. The 45 mm width and 58 mm height fit standard TeSys K rail or screw-mounting footprints — common in small-to-medium control panels where space is tight. The 115 V AC coil is a North American standard control voltage; verify your control transformer or PLC output matches.

Frequently asked questions

What are the key motor power ratings for this contactor?

It is rated for 4 kW at 480 V, 500–600 V, 660–690 V, 380–415 V, and 440 V AC, and 2.2 kW at 220–230 V AC, all at 50/60 Hz. The AC-3 operational current is 9 A at ≤440 V.

What is the physical size of the LC7K09017FE7?

Width 45 mm, height 58 mm, depth 57 mm. It fits the standard TeSys K panel footprint.

What compliance documentation is available for this part?

The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 railway fire compliance. The TeSys K series is typically UL, CSA, CE, and CCC certified; specific documentation should be confirmed at order.

What is the closest alternative to this contactor in the TeSys K family?

Within the TeSys K range, the key variant is coil voltage — the LC7K09017FE7 uses a 115 V AC coil. A sibling with a different coil voltage (e.g., 24 V AC/DC or 230 V AC) would be the same physical contactor with a different order code. No pin-compatible drop-in from another series exists without footprint changes.

MPN
LC7K09017FE7