Specifications

LC7K12004F7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC7K12004F7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC7K12004F7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC7K12004F7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC7K12004F7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
LC7K12004F7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC7K12004F7 is a TeSys K 4-pole contactor with a 110 V AC 50/60 Hz control coil, designed for switching resistive loads under utilisation category AC-1. Rated operational current is 20 A in AC-1 at Ue ≤ 440 V, with a rated breaking capacity of 110 A at 440 V, 80 A at 500 V, and 70 A at 660...690 V per IEC 60947. The power circuit impedance averages 3 mOhm at Ith 20 A 50 Hz, and heat dissipation is 3 W.

Standards, approvals, and lifecycle

This contactor carries approvals to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, with an insulation voltage rating of 690 V per IEC 60947-4-1 and 600 V per UL 508.

Mounting, wiring, and environment

Mounts on a rail or plate; screw clamp terminals accept 1 or 2 conductors from 0.34 to 4 mm² (solid or flexible with/without ferrule), tightened to 1.3 N·m. IP2X finger protection per VDE 0106; flame retardance V1 per UL 94. Dimensions: 45 mm wide, 58 mm high, 57 mm deep — fits standard 45 mm modular enclosure spacing.

Durability and safety

Mechanical durability is 10 Mcycles; electrical durability is 0.3 Mcycles at 20 A AC-1 ≤ 440 V. Maximum operating rate is 3600 cycles per hour. Safety reliability: B10d = 1,369,863 cycles at nominal load and 20,000,000 cycles with mechanical load per EN/ISO 13849-1. Withstands shocks up to 15 Gn (closed) and vibrations up to 4 Gn, 5...300 Hz (closed) per IEC 60068-2-27 and IEC 60068-2-6.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole contactor with a 110 V AC 50/60 Hz control coil, rated 20 A in AC-1 for resistive loads, with a breaking capacity of 110 A at 440 V. Mechanical durability is 10 Mcycles.

What compliance documentation does this brand provide?

The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94.

What is the mounting and wiring specification?

Mounts on a rail or plate. Screw clamp terminals accept 1 or 2 conductors from 0.34 to 4 mm², tightened to 1.3 N·m. Dimensions are 45 x 58 x 57 mm.

MPN