Skip to main content
Schneider Electric LC7K12017B7 — Contactors

TeSys K LC7K12017B7 Contactor, 3P, 12 A AC-3, 24 V AC Coil

MPNLC7K12017B7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 12 A, 1 NC aux, 24 V AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC7K12017B7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC7K12017B7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1 AC-4
LC7K12017B7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC7K12017B7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC7K12017B7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC7K12017B7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz
Heat dissipation3 W
Range of productTeSys K
Device short nameLC7K
Compatibility codeLC7K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 12 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 °C - >= 15 min for power circuit

Product details

The Schneider Electric TeSys K LC7K12017B7 is a three-pole contactor rated for control applications, with a 24 V AC coil and one normally closed auxiliary contact. Its rated operational current is 12 A in AC-3 duty at ≤440 V, and it carries motor power ratings of 4 kW at 480 V AC, 5.5 kW at 380–415 V AC, and 3 kW at 220–230 V AC (50/60 Hz). The utilisation categories cover AC-3 (motor starting), AC-1 (resistive loads), and AC-4 (plugging/inching).

The 4 kW / 5.5 kW motor power figures across voltage ranges let you match the contactor to standard three-phase induction motors without oversizing. Flame retardance meets V1 per UL 94, plus NF F 16-101 and NF F 16-102 requirements — relevant for rail or transit applications where fire-smoke-toxicity limits apply.

Physical integration

The contactor measures 45 mm wide, 58 mm high, and 57 mm deep. The 3 NO pole composition with 1 NC auxiliary means it can directly replace a similar TeSys K unit in a control panel without re-wiring the auxiliary circuit, provided the coil voltage matches.

Frequently asked questions

What is the closest alternative to LC7K12017B7 in the TeSys family?

No official successor order code is listed in the lifecycle record. A form-fit-function replacement would need to match the 3P, 12 A AC-3, 24 V AC coil, and 1 NC auxiliary configuration — but any cross-reference must be verified against the original panel's wiring and mounting constraints.

What are the key ratings for this contactor?

Rated operational current is 12 A in AC-3 at ≤440 V, with motor power ratings of 4 kW at 480 V AC, 5.5 kW at 380–415 V AC, and 3 kW at 220–230 V AC. Coil is 24 V AC. Heat dissipation is 3 W.

MPN
LC7K12017B7