Skip to main content
Schneider Electric LC8K090047M7

Schneider Electric LC8K090047M7

MPNLC8K090047M7
Obsolete

TeSys K changeover contactor, 4P, AC,1 <= 440 V 20 A, 220...230 VAC coil

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC8K090047M7 key specifications
ParameterValue
Interlocking typeMechanical
Control circuit typeAC 50/60 Hz silent
Product or component typeChangeover contactor
Coil voltage220...230 V AC 50/60 Hz
VoltagePower circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
[Ue] rated operational voltagePower circuit 690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit
Breaking capacity110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Ie] rated operational current20 A (at 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit
[Ith] conventional free air thermal current20 A (at 122 °F (50 °C)) for power circuit

All specifications

LC8K090047M7 additional specifications
ParameterValue
Inrush power in3 VA (at 68 °F (20 °C))
Power pole contact composition4 NO
Hold-in power consumption in3 VA (at 68 °F (20 °C))
Poles description4P
Utilisation categoryAC-1
IP degree of protectionIP20 VDE 0106
Mounting supportPlate Rail
Connections - terminalsFaston terminals 2 2.8 mm Faston terminals 1 6.35 mm
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (57 mm)
Width3.5 in (90 mm)
Height2.3 in (58 mm)
Electrical durability0.18 Mcycles 20 A AC-1 1.3 Mcycles 9 A AC-3 <= 440 V
Mechanical durability5 Mcycles
StandardsNF C 63-110 BS 5424 IEC 60947 VDE 0660
RangeTeSys
Category18400-WORLD SERVICE PARTS(CONTACTORS)
Operating time30...40 ms coil energisation and NO closing 30 ms coil de-energisation and NO opening
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Heat dissipation3 W
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC8K
Device applicationControl
Device presentationPreassembled with reversing power busbar
Overvoltage categoryIII
Protective treatmentTC IEC 60068 TC DIN 50016
Contactor applicationResistive load
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Associated fuse rating25 A gG at 25 A aM for power circuit
Maximum operating rate3600 cyc/h
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947
Ambient air temperature for storage-58...176 °F (-50...80 °C)
Ambient air temperature for operation-13...122 °F (-25...50 °C)
MPN
LC8K090047M7