Skip to main content
Schneider Electric LMC20A1309

Schneider Electric LMC20A1309

MPNLMC20A1309
Active

Lexium motion servo drive Controller - 24 V DC - 0.5 A

$4,282.25Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LMC20A1309 key specifications
ParameterValue
Memory typeFlash EPROM 1 MB application NVRAM 60 kB data storage RAM 1 MB application
Connector type1 RJ45 for Modbus protocol 1 RJ45 for Modbus TCP network 9-way male SUB-D connector for CANopen machine bus 9-way male SUB-D connector for CANopen Motionbus Screw-type, 5 contacts, 5.08 pitch for DeviceNet fieldbus
Range of productLexium Controller
Discrete input type12 mA master encoder input for 2 kOhm 7 mA discrete input for 3 kOhm 7 mA event-triggered input for 3 kOhm 7 mA touch probe input for 3 kOhm
Type of polarization10 kOhm for Modbus protocol
Power supply circuit typeDC
Product or component typeMotion servo drive controllers
Communication network typeICMP IP conforming to RFC791
Communication transport typeTCP conforming to RFC793 UDP
Power supply voltage24 V
Discrete input voltage5.5 V DC for master encoder input 24 V DC (voltage limits: 19...30 V) for discrete input 24 V DC (voltage limits: 19...30 V) for event-triggered input 24 V DC (voltage limits: 19...30 V) for touch probe input
Discrete output voltage24 V DC 19...30 V

All specifications

LMC20A1309 additional specifications
ParameterValue
Power supply voltage limits19...30 V
Inrush current10 A for 0.2 ms
Maximum supply current0.5 A
Discrete output current200 mA
Maximum output short-circuit current1 A
IP degree of protectionIP20
Physical interface2-wire RS 485 for Modbus protocol 2-wire RS 485 for Modbus TCP network Ethernet 2 for Modbus TCP network
Communication service10 PDOs per slave for CANopen machine bus 2 SDOs per cycle for CANopen machine bus CiA DSP 301 V4.02 for CANopen machine bus CiA DSP 405 for CANopen machine bus Note guarding, heartbeat for CANopen machine bus 2 PDOs per slave (1 transmit and 1 receive) for CANopen Motionbus 2 SDOs per cycle (1 read and 1 write) for CANopen Motionbus CiA DSP 301 V4.02 for CANopen Motionbus CiA DSP 405 for CANopen Motionbus Emergency for CANopen Motionbus Note guarding, heartbeat for CANopen Motionbus Communication scanner assemblies 100 and 101 for DeviceNet fieldbus Monitoring inhibitable for DeviceNet fieldbus Periodic exchange mode on inputs : polled, change of state, cyclic for DeviceNet fieldbus Periodic exchange mode on outputs : polled for DeviceNet fieldbus Time out can be set for DeviceNet fieldbus Configurable time out for Modbus protocol Diagnostics (08) for Modbus protocol Read device identification (43) for Modbus protocol Read holding registers (03), 121 words maximum for Modbus protocol Write multiple registers (16), 121 words maximum for Modbus protocol Write single register (06) for Modbus protocol BOOTP for Modbus TCP network DHCP for Modbus TCP network Diagnostics (08) for Modbus TCP network FTP for web server for Modbus TCP network Monitoring inhibitable for Modbus TCP network Read device identification (43) for Modbus TCP network Read holding registers (03), 121 words maximum for Modbus TCP network SNMP for Modbus TCP network Time out adjustable from 0.5...60 s for Modbus TCP network Write multiple registers (16), 121 words maximum for Modbus TCP network Write single register (06) for Modbus TCP network
Communication data linkLLC : IEEE 802.2 for Modbus TCP network MAC : IEEE 802.3 for Modbus TCP network
Communication port protocolCANopen Motionbus Modbus protocol Modbus TCP network CANopen machine bus DeviceNet fieldbus
Electrical connection1 HE-10 connector discrete input 1 HE-10 connector event-triggered input 1 HE-10 connector touch probe input 1 high density 15-way female SUB-D connector master encoder input
Response time150 µs at state 1 for logic output 250 µs at state 0 for logic output
Shock resistance15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity10...95 % for operation, without condensation 5...95 % for storage, without condensation conforming to IEC 61131-2
Operating altitude0...2000 m
Vibration resistance1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 5...13 Hz) conforming to EN/IEC 60068-2-6
StandardsEN/IEC 61800-3 environment 1 EN/IEC 61800-5-1 EN/IEC 61800-3 environment 2
MarkingCE
Cycle time2 ms for 4 synchronized axes 4 ms for 8 synchronized axes
InsulationDiscrete input for between input channels with internal logic via optical coupler Event-triggered input for between input channels with internal logic via optical coupler Logic output for between output channels with internal logic via optical coupler Master encoder input for 2500 V Touch probe input for between input channels with internal logic via optical coupler
Web serverClass C20, Modbus TCP network
Data format8 bits, no parity, 1 stop for Modbus protocol
Filter time0.5 µs at state 0 for touch probe input(s) 1 µs at state 1 for touch probe input(s) 15 µs at state 1 for discrete input(s) 15 µs at state 1 for event-triggered input(s) 70 µs at state 0 for discrete input(s) 70 µs at state 0 for event-triggered input(s)
Exchange modeHalf duplex and full duplex Modbus TCP network
Component nameLMC
Realtime clockBuilt-in for 20 days
Installed device8 Lexium 05 or Lexium 15 servo drives or SD3 28A stepper drives for CANopen Motionbus
Local signalling1 LED - activity for CANopen machine bus 1 LED - activity for CANopen Motionbus 1 LED - activity for DeviceNet fieldbus 1 LED - activity for Modbus protocol 1 LED - activity for Modbus TCP network
Method of accessMaster CANopen machine bus Master CANopen Motionbus Slave Modbus protocol
Transmission rate1 Mbps for bus length of 15 m for CANopen machine bus 1 Mbps for bus length of 15 m for CANopen Motionbus 10/100 Mbps, autodetected for Modbus TCP network 125 kbps, 250 kbps or 500 kbps for DeviceNet fieldbus 19.6 kbps or 38.4 kbps for Modbus protocol 250 kbps for bus length of 250 m for CANopen Motionbus 50 kbps for bus length of 1000 m for CANopen machine bus 500 kbps for bus length of 80 m for CANopen Motionbus
Input compatibilityEncoder with open collector output, 5 V power supplied for master encoder Encoder with push-pull output, 5 V power supplied for master encoder Encoder with RS422 compatible differential outputs, 5 or 24 V power supplied for master encoder Universal encoder with SSI output, 24 V power supplied for master encoder
Number of addresses1...32 for CANopen machine bus 1...63 for DeviceNet fieldbus 1...247 for Modbus protocol
Discrete input logicPositive logic (source) for discrete input
Mode of transmissionRTU for Modbus protocol
Application structure1 master task 1 auxiliary task 2 event-triggered tasks
Discrete input number1 master encoder discrete input(s) 2 event-triggered discrete input(s) 2 touch probe discrete input(s) 8 discrete discrete input(s)
Discrete output logic2 positive logic (source)
Discrete output number8
Electromagnetic compatibilityElectrostatic discharge level 3 conforming to EN/IEC 61000-4-2 Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3 Voltage/current impulse level 3 conforming to EN/IEC 61000-4-5
Exact time for 1 kinstruction< 120 µs (in structured language, 60 % Boolean, 20 % numerical, 20 % floating point)
Ambient air temperature for storage-25...70 °C conforming to IEC 61131-2
Ambient air temperature for operation0...50 °C
MPN
LMC20A1309