Skip to main content
Schneider Electric LP1SK0600BD

Schneider Electric LP1SK0600BD

MPNLP1SK0600BD
Obsolete

Square D LP1SK0600BD 12A Contactor|Square D LP1SK0600BD 12A Contactor

$17.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP1SK0600BD key specifications
ParameterValue
Control circuit typeDC standard
Product or component typeMini contactor
Coil voltage24 V DC
Voltage690 V IEC 60947 690 V VDE 0110 group C 690 V BS 5424 690 V UL 508 690 V CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.85...1.1 Uc (at Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
[Ue] rated operational voltagePower circuit 690 V AC 50/60 Hz
[Icw] rated short-time withstand current50 A 131 °F (55 °C) for power circuit
Breaking capacity52 A at 52 A at <= 400 V for power circuit conforming to IEC 60947
[Ie] rated operational current12 A (at <131 °F (55 °C)) AC AC-1
[Ith] conventional free air thermal current12 A (at 131 °F (55 °C)) for power circuit
Inrush power in2.2 W 68 °F (20 °C))
Hold-in power consumption in2.2 W 68 °F (20 °C)

All specifications

LP1SK0600BD additional specifications
ParameterValue
Power pole contact composition2P
Pole contact composition2 NO
Utilisation categoryAC-1
IP degree of protectionIP2X VDE 0106
Mounting supportRail
Connections - terminalsPower circuit connector 1 0.0005...0.009 in² (0.35...6 mm²)flexible with cable end Power circuit connector 1 0.0008...0.009 in² (0.5...6 mm²)flexible without cable end Power circuit connector 1 0.002...0.009 in² (1.5...6 mm²)solid Power circuit connector 2 0.0005...0.002 in² (0.35...1.5 mm²)flexible with cable end Power circuit connector 2 0.0005...0.004 in² (0.35...2.5 mm²)flexible without cable end Power circuit connector 2 0.002...0.006 in² (1.5...4 mm²)solid
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (55.5 mm)
Width1.06 in (27 mm)
Height2.2 in (56 mm)
Mechanical durability10 Mcycles
StandardsEN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
CategoryUS10NET39997
Operating time4...6 ms coil de-energisation and NO opening 8...12 ms coil energisation and NO closing
Heat dissipation2.2 W
Average impedance4 mOhm - Ith 12 A 50 Hz
Device short nameLP1SK
Tightening torque7.08 lbf.in (0.8 N.m) connector pozidriv No 1
Protective treatmentTC IEC 60068 TC DIN 50015
Contactor applicationResistive load
Associated fuse rating16 A gI at <= 440 V for power circuit conforming to IEC 60947
Maximum operating rate1200 cyc/h
Irms rated making capacity66 A at 690 V AC conforming to IEC 60947 66 A at 690 V AC conforming to NF C 63-110
Ambient air temperature for storage-58...158 °F (-50...70 °C)
Ambient air temperature for operation-4...122 °F (-20...50 °C)
MPN
LP1SK0600BD