Schneider Electric LP2K0601ED3 — Contactors

Schneider LP2K0601ED3 TeSys K Reversing Contactor, 6A AC-3

MPNLP2K0601ED3
Obsolete

Schneider Electric TeSys K reversing contactor, LP2K0601ED3, 3P, AC-3 <= 440 V 6 A, 1 NC auxiliary, 48 V DC coil, preassembled with reversing power busbar.

$38.05Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K0601ED3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LP2K0601ED3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LP2K0601ED3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K0601ED3 — Environmental
ParameterValue
IP degree of protectionIP20 VDE 0106
Operating altitude6561.68 ft (2000 m) without derating
Mechanical robustnessShocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
Protective treatment / pollution degreeTC IEC 60068 TC DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K0601ED3 — Mechanical
ParameterValue
Width3.5 in (90 mm)
Height2.3 in (58 mm)
Depth2.2 in (57 mm)

Product details

What this reversing contactor is and why it matters

The LP2K0601ED3: It is preassembled with a reversing power busbar, so the mechanical interlock and bus work are already in place for a motor reversing pair. At 6 A AC-3, it handles a 2.2 kW (3 HP) motor at 400 V three-phase.

Lifecycle status and sourcing reality

This part is marked obsolete by the manufacturer. Availability runs through independent surplus and broker channels. Quantities are lot-specific and confirmed at RFQ — no stock-holding claim is made here. The genuine part is sourced per the BOM line; same part, different passport.

The contactor measures 2.2 in (57 mm) deep, 3.5 in (90 mm) wide, and 2.3 in (58 mm) high. The IP20 finger-safe enclosure (VDE 0106) means it can be mounted in a control cabinet without additional shrouding on the front face, though the power terminals remain touch-safe only to the IP20 standard. Flame retardance is V1 per UL 94, with additional compliance to NF F 16-101 and NF F 16-102 — relevant for rolling-stock or rail-adjacent installations where fire-smoke-toxicity requirements apply. Operating altitude is 2000 m without derating; above that, the dielectric strength and thermal dissipation must be recalculated per IEC 60947-1.