Skip to main content
Schneider Electric LP2K09013BD3 — Contactors

Schneider TeSys K LP2K09013BD3 Reversing Contactor, 9 A AC-3

MPNLP2K09013BD3
Active

Schneider Electric TeSys K reversing contactor, LP2K09013BD3, 3P, AC-3 9 A at 440 V, 24 V DC coil, 1 NC auxiliary, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP2K09013BD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K09013BD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-1 AC-4
LP2K09013BD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K09013BD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K09013BD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Rated AC-3 at 9 A up to 440 V, it handles reversing duty on small three-phase motors (pumps, conveyors, fans) where direction change is needed under load. The 24 V DC coil keeps control voltage low and safe for PLC or relay outputs.

The preassembled reversing busbar eliminates the need to build a mechanical interlock and power crossover from separate parts, saving panel space and wiring time.

Frequently asked questions

What is the closest alternative if LP2K09013BD3 is unavailable?

Within the TeSys K family, the standard (non-reversing) contactor LP1K0901BD3 shares the same coil voltage and main contact rating but lacks the mechanical interlock and reversing busbar. For a reversing application, the LP2K0901BD3 (with 1 NO auxiliary instead of 1 NC) is the closest functional match — verify the auxiliary contact configuration against your control circuit before substituting.

What compliance documentation is available for this part?

The contactor carries V1 flame retardance per UL 94, IP20 per VDE 0106, and compliance with NF F 16-101/102 for railway applications. Standard Schneider Electric declarations of conformity (CE, UKCA, EAC) and material compliance (RoHS, REACH) are available through the product documentation portal.

MPN
LP2K09013BD3