Schneider Electric LP2K09013ED — Contactors

TeSys K LP2K09013ED reversing contactor, 3P, 9A AC-3, 48 VDC

MPNLP2K09013ED
Obsolete

Schneider Electric TeSys K reversing contactor, LP2K09013ED, 3 poles, AC-3 ≤440 V 9 A, 1 NC auxiliary, 48 V DC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K09013ED — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K09013ED — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-3 AC-4
LP2K09013ED — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K09013ED — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K09013ED — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It carries 3 NO power poles rated AC-3 at 9 A up to 440 V, plus one NC auxiliary contact, and a 48 V DC coil. The IP20 finger-safe enclosure (VDE 0106) means it's safe for panel mounting without additional shrouding — standard for control cabinet use.

This part is marked obsolete by the manufacturer.

AC-3 rating of 9 A at 440 V governs motor switching. The 48 V DC coil is a control-voltage choice common in safety circuits. Mechanical robustness specs (15 Gn shocks closed, 4 Gn vibration closed per IEC 60068-2-27 and -2-6) mean it holds in on high-vibration environments like conveyors or compressors — but the IP20 rating limits it to clean, dry indoor panels.

Frequently asked questions

What are the key ratings for this reversing contactor?

AC-3 motor switching at 9 A up to 440 V, 48 V DC coil, 3 NO power poles plus 1 NC auxiliary contact. Rated operational voltage is 690 V AC for the power circuit. IP20 finger-safe enclosure.

What compliance documentation is available for LP2K09013ED?

The part carries V1 flame retardance per UL 94, and meets NF F 16-101 and NF F 16-102 requirements. Protective treatment conforms to IEC 60068 and DIN 50016. No RoHS or REACH statements are in the record.

MPN
LP2K09013ED