It is preassembled with the reversing power busbar, so it arrives ready to wire into a motor-reversing circuit without sourcing separate interlock hardware. IP20 finger-safe terminals (VDE 0106) mean it mounts inside a control cabinet; the enclosure provides the environmental seal. The 200 V DC coil is a less common voltage — verify your control transformer or DC supply matches before committing the BOM line.
Integration Notes for a Reversing Contactor
The LP2K0901LD is a 3-pole reversing contactor with mechanical and electrical interlock built into the preassembled busbar. This eliminates the risk of both contactors closing simultaneously — a direct short across the supply if they do. The single NC auxiliary (1 NC) is typically wired into the opposite contactor's coil circuit as an additional electrical interlock — standard practice for reversing starters. The 200 V DC coil draws a holding current that is lower than the pick-up surge. If your control supply is a DC bus with other loads, confirm the inrush does not pull the bus below the dropout threshold of other devices on the same rail.