Skip to main content
Schneider Electric LP2K12004ND3 — Contactors

Schneider Electric LP2K12004ND3 TeSys K Changeover Contactor

MPNLP2K12004ND3
Obsolete

Schneider Electric TeSys K series, LP2K12004ND3 changeover contactor, 4 poles, 60 V DC coil, preassembled with reversing power busbar, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K12004ND3 — Identification
ParameterValue
Product / component typeChangeover contactor
Series / rangeTeSys
ApplicationResistive load
LP2K12004ND3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1
LP2K12004ND3 — Contacts & Poles
ParameterValue
Pole configuration4P
LP2K12004ND3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12004ND3 — Approvals
ParameterValue
StandardsVDE 0660 BS 5424 NF C 63-110 IEC 60947
LP2K12004ND3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It switches resistive loads (AC-1 utilisation category) across four poles, with a 60 V DC coil that includes a built-in bidirectional peak limiting diode suppressor — no external flyback diode needed on the coil circuit. The 4-pole configuration gives you two sets of normally-open and normally-closed power contacts for forward/reverse motor control or source transfer switching.

Rated insulation voltage (Ui) is 690 V per IEC 60947-4-1 and 600 V per UL 508 / CSA C22.2 No 14, so the contactor is rated for 480 V and 600 V class systems in North America and 690 V class in IEC territories. The 60 V DC control coil holds in at 0.8 to 1.15 Uc (48 to 69 V DC) and drops out between 0.1 and 0.75 Uc (6 to 45 V DC) — this wide dropout margin means it will not nuisance-drop on a sagging 48 V bus, but also that a slow-decay DC supply may hold it closed longer than expected. Mechanical interlocking is built into the reversing assembly, preventing both contactors from closing simultaneously — a standard requirement for reversing starters.

Mounts on DIN rail or plate (rail/plate mounting support). Screw-clamp terminals accept 1.5 to 4 mm² solid or 0.75 to 4 mm² flexible (with or without ferrules), torqued to 1.3 N·m.

Compliant with IEC 60947, VDE 0660, BS 5424, and NF C 63-110. Flame retardance rated V1 per UL 94, plus meets NF F 16-101/102 for railway fire-smoke-toxicity. Protective treatment TC per IEC 60068 and DIN 50016 for tropical climate resistance.

Frequently asked questions

What is the closest alternative in the TeSys K family?

Within the TeSys K range, the LP2K series covers reversing contactors preassembled with busbars. The LP2K12004ND3 is the 4-pole, 60 V DC variant. A 3-pole version (LP2K09004ND3) exists for applications not requiring the fourth pole, but pin-compatibility depends on your wiring scheme — the 4-pole adds an extra set of terminals per side.

What compliance documentation is available for this part?

The contactor carries IEC 60947, VDE 0660, BS 5424, and NF C 63-110 standards. Flame retardance is V1 per UL 94. It also meets NF F 16-101/102 for railway applications and has protective treatment per IEC 60068 and DIN 50016 for tropical environments. UL and CSA listings are confirmed for the insulation voltage ratings (600 V per UL 508, 600 V per CSA C22.2 No 14).

What is the depth of this component?

The LP2K12004ND3 has a depth of 57 mm, with a width of 90 mm and height of 58 mm.

MPN
LP2K12004ND3