Skip to main content
Schneider Electric LP2K12015MD — Contactors

Schneider TeSys K LP2K12015MD Reversing Contactor, 12 A AC-3

MPNLP2K12015MD
Active

Schneider TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC auxiliary, 220 V DC coil, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K12015MD — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K12015MD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LP2K12015MD — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K12015MD — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12015MD — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Rated 12 A in AC-3 duty at up to 440 V, it switches three-phase motor loads within that current envelope; the same pole stack also carries AC-1 resistive and AC-4 plugging/inching duty ratings. The single NC auxiliary contact provides a feedback or interlock signal without an add-on block.

IP20 finger-safe terminals per VDE 0106 suit panel-mount enclosures with a gland plate; no washdown rating, so keep this behind a cabinet door. The contactor holds closed through 15 Gn shock on Z axis and 4 Gn vibration at 5–300 Hz — stiff enough for a machine-mounted sub-panel on a press or conveyor drive. Operating range is -25 to 50 °C ambient; derate above 2000 m altitude.

Frequently asked questions

What is the closest alternative to LP2K12015MD in the TeSys family?

The TeSys K series has been superseded by the TeSys D range. A direct functional match would be a TeSys D reversing contactor assembly with a 220 V DC coil and a 12 A AC-3 rating, but the DIN rail footprint and the reversing busbar layout differ — verify the mounting hole pattern and interlock wiring before substitution.

What are the key ratings for LP2K12015MD?

Three-pole reversing contactor, 12 A in AC-3 duty at ≤440 V, 220 V DC coil, one NC auxiliary contact. Also rated for AC-1 resistive and AC-4 plugging duty.

MPN
LP2K12015MD