Skip to main content
Schneider Electric LP2K1201JD3 — Contactors

Schneider TeSys K LP2K1201JD3 Reversing Contactor, 12 A, 12

MPNLP2K1201JD3
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 12 V DC coil, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K1201JD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K1201JD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-1 AC-4
LP2K1201JD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1201JD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1201JD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LP2K1201JD3 is a TeSys K reversing contactor — a 3-pole unit rated AC-3 ≤440 V at 12 A, with a 12 V DC coil and one NC auxiliary contact. It arrives preassembled with the reversing power busbar, so the mechanical interlock and bus connections are already in place. That saves panel-build time on motor-reversing circuits for conveyors, hoists, or any load that needs direction change.

The LP2K1201JD3 is listed as Obsolete.

AC-1 (resistive) and AC-4 (inching/plugging) utilisation categories are also listed, so the contactor is rated for those duty cycles too. The 12 V DC coil draws from a control supply common in low-voltage DC panels; verify your control transformer or power supply can deliver the inrush without droop. IP20 protection per VDE 0106.

Mechanical robustness and panel fit

The contactor is rated for 15 Gn shock on the Z axis when closed, and 10 Gn when open, per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz. That is enough for most industrial machinery but not for extreme off-road or marine engine mounts without additional damping.

Frequently asked questions

What are the key ratings for this reversing contactor?

It is a 3-pole reversing contactor rated AC-3 ≤440 V at 12 A, with a 12 V DC coil and one NC auxiliary contact. It covers AC-1 and AC-4 utilisation categories as well. The unit is preassembled with the reversing power busbar.

What is the ambient temperature range for operation?

The ambient air temperature for operation is -25 to 50 °C. Storage range is -50 to 80 °C.

What approvals or compliance documentation does this part carry?

The contactor carries IP20 protection per VDE 0106, flame retardance V1 conforming to UL 94, and protective treatment TC conforming to IEC 60068 and DIN 50016. Operating altitude is 2000 m without derating.

MPN