Skip to main content
Schneider Electric LP2K1201SD3 — Contactors

Schneider Electric LP2K1201SD3 TeSys K Reversing Contactor,

MPNLP2K1201SD3
Active

Schneider Electric TeSys K reversing contactor, LP2K1201SD3, 3P, AC-3 ≤440 V 12 A, 1 NC, 72 V DC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP2K1201SD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K1201SD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-1 AC-4
LP2K1201SD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1201SD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1201SD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Its AC-3 rating at ≤440 V is 12 A, meaning it can switch a three-phase induction motor drawing up to that current under full load.

The utilisation categories cover AC-1 (resistive), AC-3 (squirrel-cage motor starting/running), and AC-4 (plugging/inching). For a motor load, the AC-3 figure governs — 12 A at ≤440 V. The contactor is rated for 690 V AC 50/60 Hz on the power circuit, so it can be used on 400 V or 480 V systems with appropriate derating. The single NC auxiliary contact (1 NC) is built in; no add-on block needed for basic interlocking. IP20 protection (VDE 0106) means it is finger-safe but not sealed — suitable for enclosure-mounted panels, not washdown environments. Flame retardance meets UL 94 V1 and NF F 16-101/102, which is relevant for rail and industrial compliance.

Frequently asked questions

What are the key ratings for the LP2K1201SD3?

It is a 3-pole reversing contactor rated AC-3 12 A at ≤440 V, with a 72 V DC coil and one NC auxiliary contact. The power circuit is rated for 690 V AC 50/60 Hz. IP20 protected, operating temperature -25 to 50 °C.

What compliance does the LP2K1201SD3 meet?

Flame retardance meets UL 94 V1 and NF F 16-101/102. The contactor also conforms to IEC 60068 for mechanical robustness (shock and vibration) and IEC 60068 for protective treatment (TC).

MPN
LP2K1201SD3