Skip to main content
Schneider Electric LP2K1210BD

LP2K1210BD TeSys K Reversing Contactor, AC-3

MPNLP2K1210BD
Active

TeSys K reversing contactor, LP2K1210BD, 3-pole, AC-3 rated, preassembled with reversing busbar.

$44.45Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LP2K1210BD key specifications
ParameterValue
Product or component typeReversing contactor
[Ue] rated operational voltagePower circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit
Power pole contact composition3 NO
Poles description3P
Utilisation categoryAC-3 AC-3e AC-4 AC-1
IP degree of protectionIP20 VDE 0106
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (57 mm)
Width3.5 in (90 mm)
Height2.3 in (58 mm)
RangeTeSys
CategoryUS10I1222322

All specifications

LP2K1210BD additional specifications
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Device short nameLP2K
Device applicationControl
Device presentationPreassembled with reversing power busbar
Protective treatmentTC IEC 60068 TC DIN 50016
Contactor applicationMotor control Resistive load
Mechanical robustnessShocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
Ambient air temperature for storage-58...176 °F (-50...80 °C)
Ambient air temperature for operation-13...122 °F (-25...50 °C)

Product details

It carries AC-3 and AC-4 utilisation ratings, so it handles motor starting inrush and switching off at full speed, plus AC-1 for resistive loads. The unit ships assembled with a reversing power busbar — that saves you the time of wiring an external interlock and bus arrangement. IP20 finger protection is standard, and the operating range goes from -25°C to 50°C ambient, which covers most panel environments.

Frequently asked questions

What utilisation categories does this reversing contactor cover?

It covers AC-3, AC-3e, AC-4 (for motor control) and AC-1 (for resistive loads), as listed in the spec.

What is the ambient temperature range for operation?

The LP2K1210BD operates between -25°C and 50°C, with storage from -50°C to 80°C.

MPN