Skip to main content
Schneider Electric LP4K12015FW3 — Contactors

Schneider LP4K12015FW3 TeSys K Contactor, 12A AC-3, 110V DC

MPNLP4K12015FW3
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V 12A, 1 NC aux, 110V DC coil, built-in bidirectional peak limiting diode suppressor.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP4K12015FW3 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LP4K12015FW3 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-1 AC-3
LP4K12015FW3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP4K12015FW3 — Environmental
ParameterValue
Flame retardanceV1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
LP4K12015FW3 — Mechanical
ParameterValue
Width1.8 in (45 mm)
Height2.3 in (58 mm)
Depth2.2 in (57 mm)
LP4K12015FW3 — Other specifications
ParameterValue
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Range of productTeSys K
Device short nameLP4K
Inrush power in1.8 W 68 °F (20 °C))
Compatibility codeLP4K
Pole contact composition3 NO
Hold-in power consumption in1.8 W 68 °F (20 °C)
[Ie] rated operational current20 A (at 12 A at 16 A (at 10 MOhm for signalling circuit

Product details

The LP4K12015FW3 is a 3-pole TeSys K contactor rated 12 A in AC-3 duty at ≤440 V, with a 110 V DC coil. It carries a built-in bidirectional peak limiting diode suppressor across the coil, which simplifies panel wiring — no external flyback diode needed. Rated operational current is 12 A in AC-3 (motor switching), 16 A in AC-1 (resistive), and 20 A in AC-4 (frequent inching/plugging). The 3 NO main poles handle 3-phase loads; the 1 NC auxiliary contact is built in. Coil hold-in power is 1.8 W at 20 °C, with inrush the same value — the DC coil draws steady current, no AC hum. The diode suppressor means polarity must be observed: reverse connection shorts the diode.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 12 A in AC-3 (≤440 V), 16 A in AC-1, and 20 A in AC-4. Coil is 110 V DC with built-in diode suppression. Three normally-open main poles, one normally-closed auxiliary contact.

What compliance documentation exists for this part?

The part carries a V1 flame retardance rating per UL 94 and meets NF F 16-101/102 requirements for fire behavior. No RoHS/REACH declarations are in the provided record; check with the supplier at time of order.

How do I source this obsolete contactor?

Since it is obsolete, sourcing is through independent distributors and brokers. Submit an RFQ with quantity and target date code; availability depends on remaining surplus stock.

MPN
LP4K12015FW3