Schneider Electric LP5K1210EW3 — Contactors

Schneider LP5K1210EW3 TeSys K Reversing Contactor, 12A, 48V

MPNLP5K1210EW3
Active

Schneider Electric TeSys K reversing contactor, LP5K1210EW3, 3P, AC-3 12 A at 440 V, 48 V DC coil, 1 NO auxiliary, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP5K1210EW3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP5K1210EW3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LP5K1210EW3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP5K1210EW3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP5K1210EW3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LP5K1210EW3 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit rated AC-3 at 12 A up to 440 V, with a 48 V DC coil and one normally open auxiliary contact. AC-4 covers plugging and inching, and AC-1 covers resistive loads, so it's not limited to just motor work.

Lifecycle reality — this one's obsolete

Schneider lists the LP5K1210EW3 as obsolete. No factory production or standard lead time applies. Sourcing goes through surplus channels against an RFQ. No official successor order code appears in the record. If you need a drop-in replacement, you'll want to compare the footprint and wiring of the TeSys K frame against current TeSys Deca or TeSys Giga reversing contactors — but that's a cross-reference exercise, not a pin-compatible swap.

The contactor measures 90 mm wide by 58 mm high by 57 mm deep — fits a standard DIN-rail enclosure. Rated for ambient operation from -25 to 50 °C and storage from -50 to 80 °C. Altitude derating kicks in above 2000 m. The V1 flame-retardance rating per UL 94 and NF F 16-101 means it meets rail and industrial fire-safety requirements.

Mechanical and electrical robustness

It'll take 15 Gn shock on the Z axis with the contactor closed, and 10 Gn open — tested per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn open across 5-300 Hz. That's enough for most industrial machinery, but not for high-vibration mobile equipment. Coil is 48 V DC. The signalling circuit isolation is tested at 10 MOhm.

Frequently asked questions

What are the key ratings of the LP5K1210EW3?

It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 48 V DC coil and one normally open auxiliary contact. It also carries AC-4 and AC-1 utilisation categories.

What is the physical size of the LP5K1210EW3?

It measures 90 mm wide, 58 mm high, and 57 mm deep, with IP20 finger protection.

What compliance documentation is available for the LP5K1210EW3?

The contactor carries V1 flame retardance per UL 94, and meets NF F 16-101 and NF F 16-102 for rail fire safety. It is also tested for protective treatment per IEC 60068 and DIN 50016.

MPN
LP5K1210EW3