Skip to main content
Schneider Electric LRD33656

Schneider Electric LRD33656

MPNLRD33656
Obsolete

LRD33656 - OVERLOAD by SQUARE D

$112.73Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LRD33656 key specifications
ParameterValue
Control typeRed push-button: stop Blue push-button: reset
Network typeDC AC
Product or component typeDifferential thermal overload relay
Climatic withstandconforming to IACS E10
VoltagePower circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 750 V conforming to IEC 60947-4-1
[Ue] rated operational voltage1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV
Permissible current0.72 A at 500 V AC-15 for signalling circuit 0.06 A at 440 V DC-13 for signalling circuit
[Ith] conventional free air thermal current5 A for signalling circuit
Network frequency0...400 Hz
Phase failure sensitivityTripping current 130 % of Ir on two phase, the last one at 0
IP degree of protectionIP20 conforming to IEC 60529

All specifications

LRD33656 additional specifications
ParameterValue
Mounting supportPlate Rail
Connections - terminalsPower circuit: screw clamp terminals 1 cable(s) 4...35 mm² flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 4...35 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 4...35 mm² solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² solid without cable end
Height123 mm
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495
RangeTeSys
Flame retardanceV1 conforming to UL 94
Device short nameLRD
Relay applicationMotor protection
Tightening torqueControl circuit: 1.7 N.m - on screw clamp terminals Power circuit: 9 N.m - on screw clamp terminals
Tripping threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Dielectric strength2.2 kV at 50 Hz conforming to IEC 60947-1
Mechanical robustnessVibrations: 6 Gn conforming to IEC 60068-2-6 Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Associated fuse rating4 A gG for signalling circuit 4 A BS for signalling circuit
Thermal overload classClass 10A conforming to IEC 60947-4-1
Temperature compensation-20...60 °C
Auxiliary contact composition1 NO + 1 NC
Ambient air temperature for storage-60...70 °C
Thermal protection adjustment range80...104 A
Ambient air temperature for operation-20...60 °C without derating conforming to IEC 60947-4-1
MPN
LRD33656