Skip to main content
Schneider Electric LTMTEBD

Schneider Electric LTMTEBD

MPNLTMTEBD
Active

Electronic motor relay main unit, TeSys Tera, EtherNet TCP/IP, 24VDC

$790.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LTMTEBD key specifications
ParameterValue
ProtocolEthernet IEEE 802.3 0...159 10...100 Mbit/s, 2xRJ45 4 shielding pairs cable
Metering typeThermal memory Line, phase and average current Line to line and average voltage Motor temperature input Ground fault current Ig Active and reactive power Active and reactive energy Frequency Total voltage harmonic distortion THD (V) Total voltage harmonic distortion THD (U) Total current harmonic distortion THD (I) Phase sequence
Protection typeOverload protection Stalled rotor Locked rotor Short-circuit Undercurrent Overcurrent Current unbalance Phase reversal Phase loss Earth fault protection internal Earth fault protection external Excessive starting time Max number of start Undervoltage Overvoltage Voltage unbalance Underfrequency Overfrequency Reacceleration Temperature protection Analog input protection Communication failure Fail to stop Under power Over power Power factor variation Anti-backspin timer Block output DI interlock protection
Product or component typeMotor controller
Contacts type and composition2 NO fault signal 1 NO + 1 NC fault signal
Network and machine diagnosis typeMotor statistics Motor status Event recording Running hours counter/operating time Number of starts and stops Running hours /stop hours counter Start curve showing motor start record Pre-alarms Trip history information Alarm counters
Supply voltage limits18...30 V DC
Short-circuit withstand100 kA
Supply voltage24 V DC
Voltage690 V AC IEC 60185
[Uimp] rated impulse withstand voltage0.8 kV
Load current10 A 250 V AC/DC 5 A 30 V DC

All specifications

LTMTEBD additional specifications
ParameterValue
Input current7 mA 24 V
Current consumption56...127 mA
Current state 0 guaranteedDigital input 0...12 V 5 mA 10 ms
Current state 1 guaranteedDigital input 18...30 V 5 mA 10 ms
Permissible power480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Maximum output switching frequency2 Hz
IP degree of protectionIP20
Communication port protocolEthernet TCP/IP
Connection pitch0.3 in (7.5 mm) for supply voltage 0.2 in (5.0 mm) for others
Connections - terminalsControl circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible with ferrule with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible with ferrule with cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible stranded with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible stranded with cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)solid with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)solid with cable end
Operating altitude<= 6561.68 ft (2000 m) without derating
Depth3.5 in (90 mm)
Width4.4 in (112 mm)
Height1.8 in (45 mm)
StandardsEN/IEC 60947-4-1 UL/CSA 60947-4-1
RangeTeSys
CategoryUS10I1222335
Web servicesWeb server
Fire resistance1202 °F (650 °C) IEC 60947-1 1760 °F (960 °C) UL 94
Device short nameLTMT
Device applicationEquipment monitoring and control
Logic input number4
Measurement accuracy1 % current 0.3...3 A) 1 % current 2.5...25 A) 3 % current 7...70 A) 3 % current 10...100 A) 1 % voltage 110...690 V) +/- 2.5 % earth fault current external measurement +/- 3...5 % earth fault current internal measurement current > 0.03 A in the 0.3...3 A range) +/- 3...5 % earth fault current internal measurement current > 0.25 A in the 2.5...25 A range) +/- 3...5 % earth fault current internal measurement current > 0.7 A in the 7...70 A range) +/- 3...5 % earth fault current internal measurement current > 1 A in the 10...100 A range) +/- 2 % Temperature +/- 2 % THD measurement +/- 3...6 % power factor +/- 2...5 % active and reactive energy +/- 30 min/year internal clock
Overvoltage categoryIII
Mechanical robustnessVibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-27
Associated fuse rating0.5 A gG control circuit
Maximum operating rate1800 cyc/h
Ambient air temperature for storage-40...176 °F (-40...80 °C)
Ambient air temperature for operation-4...158 °F (-20...70 °C)
MPN
LTMTEBD