Motor Management main unit, TeSys Tera, Profibus DP, 4 DI and 3 DO, supply 100-240VAC/DC

$625.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LTMTPFM key specifications
ParameterValue
ProtocolProfibus DP 2-wire RS 485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs Profibus DP 2-wire RS 485 1...125 1.5 Mbit/s, terminal block 2 shielded twisted pairs
Metering typeThermal memory Line, phase and average current Line to line and average voltage Motor temperature input Ground fault current Ig Active and reactive power Active and reactive energy Frequency Total voltage harmonic distortion THD (V) Total voltage harmonic distortion THD (U) Total current harmonic distortion THD (I) Phase sequence
Protection typeThermal overload protection Thermal motor protection via the drive by continuous calculation of I²t Stalled rotor Phase unbalance Phase loss Phase reversal Ground fault protection Undervoltage Overvoltage Under power/over power Load shedding scheme Voltage dip management Max number of start Excessive starting time, locked rotor Power factor variation
Product or component typeMotor controller
Contacts type and composition2 NO fault signal 1 NO + 1 NC fault signal
Network and machine diagnosis typeEvent recording Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Trip history information Starting current and time Phase fault and earth fault trip counters Motor statistics Controller operations Start curve showing motor start record Pre-alarm of potential faults
Supply voltage limits85...265 V AC/DC
Short-circuit withstand100 kA
Supply voltage100...240 V AC/DC 50/60 Hz
Voltage250 V AC IEC 60185
[Uimp] rated impulse withstand voltage4 kV
Load current10 A 250 V AC/DC 5 A 30 V DC

All specifications

LTMTPFM additional specifications
ParameterValue
Input current3 mA 100...240 V
Current consumption8...62.8 mA
Current state 0 guaranteedDigital input 0...60 V 5 mA 10 ms
Current state 1 guaranteedDigital input 85...265 V 5 mA 10 ms
Permissible power480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Maximum output switching frequency2 Hz
IP degree of protectionIP20
Communication port protocolProfibus DP
Connection pitch0.3 in (7.5 mm) for supply voltage 0.2 in (5.0 mm) for others
Connections - terminalsControl circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible with ferrule with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible with ferrule with cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible stranded with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible stranded with cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)solid with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)solid with cable end
Pollution degree3
Operating altitude<= 6561.68 ft (2000 m) without derating
Depth3.5 in (90 mm)
Width4.4 in (112 mm)
Height1.8 in (45 mm)
StandardsEN/IEC 60947-4-1 UL/CSA 60947-4-1
RangeTeSys
CategoryUS10I1222335
Web servicesWeb server
Fire resistance1202 °F (650 °C) IEC 60947-1 1760 °F (960 °C) UL 94
Device short nameLTMT
Tightening torqueControl circuit 4.4 lbf.in (0.5 N.m) flat 0.1 in (3 mm)
Device applicationEquipment monitoring and control
Logic input number4
Measurement accuracy1 % current 0.3...3 A) 1 % current 2.5...25 A) 3 % current 7...70 A) 3 % current 10...100 A) 1 % voltage 110...690 V) +/- 2.5 % earth fault current external measurement +/- 3...5 % earth fault current internal measurement current > 0.03 A in the 0.3...3 A range) +/- 3...5 % earth fault current internal measurement current > 0.25 A in the 2.5...25 A range) +/- 3...5 % earth fault current internal measurement current > 0.7 A in the 7...70 A range) +/- 3...5 % earth fault current internal measurement current > 1 A in the 10...100 A range) +/- 2 % Temperature +/- 2 % THD measurement +/- 3...6 % power factor +/- 2...5 % active and reactive energy +/- 30 min/year internal clock
Overvoltage categoryIII
Mechanical robustnessVibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-27 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Associated fuse rating0.5 A gG control circuit
Maximum operating rate1800 cyc/h
Ambient air temperature for storage-40...176 °F (-40...80 °C)
Ambient air temperature for operation-4...158 °F (-20...70 °C)
MPN