LUC-AX6ES key specifications
ParameterValue
Range of productTeSys Ultra
Voltage withstand6 kV IEC 60947-6-2
Voltage insulation690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Phase failure sensitivityYes
Utilization categoryAC-43 AC-44 AC-41
Shock10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27
Altitude max6561.68 ft (2000 m)
Non-Dissipating shock wave1 kV serial mode IEC 60947-6-2 2 kV common mode IEC 60947-6-2
Depth60.96
Width45.72
Height66.04
StandardsEN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier

All specifications

LUC-AX6ES additional specifications
ParameterValue
RangeTeSys
Power90
IP ratingIP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1
Load_type3-phase motor self-cooled
Fixing_modePlug-in (front face)
Frequency40
Package_typePCE
Coil voltage48
Resistance1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12
Heat dissipation2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38
Application_typeMotor control Motor protection
Supply voltage690
Device short nameLUCA
Operating time35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 60 ms closing with LUB12 control circuit 60 ms closing with LUB32 control circuit 60 ms closing with LUB38 control circuit
Compatibility codeLUCA
Tripping threshold14.2 x Ir +/- 20 %
Switching current0.15
Storage temperature-40...185 °F (-40...85 °C)
Protective treatmentTH IEC 60068
Thermal_overload_classClass 10 40...60 Hz -13...158 °F (-25...70 °C) IEC 60947-6-2 Class 10 40...60 Hz -13...158 °F (-25...70 °C) UL 508
Immunity to microbreaks3 ms
Main function availableManual reset Protection against phase failure and phase imbalance Protection against overload and short-circuit Earth fault protection
Safe separation of circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Product specific applicationBasic protection requirements for motor starters: overload and short-circuit
Main_product_or_component_typeStandard control unit
Immunity to radioelectric fields10 V IEC 61000-4-6
Operating temperature-13
Ordering and shipping details (Category)US10I1122397