Schneider Electric LV480851
MPNLV480851
Obsolete
LV480851 - ISFL 160 60 MM BUSBAR HOOK TERMINAL 95MM2 by SCHNEIDER ELECTRIC
$106.68Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Fuse type | DIN |
| Control type | Fuse carriers handle |
| Product or component type | Fuse-switch disconnector |
| Voltage | 1000 V AC 50/60 Hz 1000 V DC |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 800 V AC 50/60 Hz AC-20 800 V DC DC-20 |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Icw] rated short-time withstand current | 5 kA for 1 s |
| [Ie] rated operational current | AC-22B: 160 A at 220/240 V AC 50/60 Hz AC-22B: 160 A at 380/415 V AC 50/60 Hz AC-22B: 160 A at 440/480 V AC 50/60 Hz AC-22B: 160 A at 500 V AC 50/60 Hz AC-22B: 100 A at 660/690 V AC 50/60 Hz AC-23B: 160 A at 220/240 V AC 50/60 Hz AC-23B: 160 A at 380/415 V AC 50/60 Hz |
| [Icm] rated short-circuit making capacity | 7.65 kA at 690 V |
| [Iq] breaking capacity with fuses (kA RMS) | 100 kA at 415 V (AC) 100 kA at 500 V (AC) 100 kA at 690 V (AC) |
| [Ith] conventional free air thermal current | 160 A ( 40 °C ) power dissipation per fuse: 12 W |
| [Ithe] conventional enclosed thermal current | 160 A at 40 °C, Power dissipation per fuse: 12 W |
All specifications
| Parameter | Value |
|---|---|
| Maximum power dissipation per pole | 19 W |
| Poles description | 1 x 3P switchable |
| Rated duty | Uninterrupted |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Mounting mode | Fixed |
| Mounting support | Busbars |
| Mounting location | One above the other |
| Mounting position | Horizontal Vertical |
| Connections - terminals | Cable connectors 95 mm² |
| Pollution degree | 3 conforming to IEC 60947 |
| Electrical shock protection class | Class II front face |
| Depth | 123 mm |
| Width | 50 mm |
| Height | 405 mm |
| Electrical durability | AC-21B: 200 cycles 690 V AC 50/60 Hz AC-22B: 200 cycles 500 V AC 50/60 Hz AC-23B: 200 cycles 415 V AC 50/60 Hz |
| Mechanical durability | 1400 cycles |
| Standards | EN/IEC 60947-1 EN/IEC 60947-3 |
| Range | FuPacT |
| Fuse size | NH00 NH000 |
| Visible break | Yes |
| Contact operation | Single-break |
| Device short name | ISFL160 |
| Tightening torque | 14 N.m |
| Device application | Equipment protection, monitoring and control Distribution |
| Signalling function | Separated fuse monitor |
| Number of fuse carriers | 3 |
| Provision for padlocking | 3 padlocks |
| Suitability for isolation | Yes conforming to EN/IEC 60947-3 |
| Contact position indicator | Yes |
| Ambient air temperature for storage | -50...85 °C |
| Ambient air temperature for operation | -20...70 °C |
MPN