fuse switch disconnector, Fupact ISFL160, 160 A, switchable fixed front connected, 100 mm busbars mounting, 3 poles

$529.87Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LV480852 key specifications
ParameterValue
Fuse typeDIN
Control typeFuse carriers handle
Product or component typeFuse-switch disconnector
Voltage1000 V AC 50/60 Hz 1000 V DC
[Ue] rated operational voltage690 V AC 50/60 Hz 800 V AC 50/60 Hz AC-20 800 V DC DC-20
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current5 kA for 1 s
[Ie] rated operational currentAC-22B: 160 A at 220/240 V AC 50/60 Hz AC-22B: 160 A at 380/415 V AC 50/60 Hz AC-22B: 160 A at 440/480 V AC 50/60 Hz AC-22B: 160 A at 500 V AC 50/60 Hz AC-22B: 100 A at 660/690 V AC 50/60 Hz AC-23B: 160 A at 220/240 V AC 50/60 Hz AC-23B: 160 A at 380/415 V AC 50/60 Hz
[Icm] rated short-circuit making capacity7.65 kA at 690 V
[Iq] breaking capacity with fuses (kA RMS)100 kA at 415 V (AC) 100 kA at 500 V (AC) 100 kA at 690 V (AC)
[Ith] conventional free air thermal current160 A ( 40 °C ) power dissipation per fuse: 12 W
[Ithe] conventional enclosed thermal current160 A at 40 °C, Power dissipation per fuse: 12 W

All specifications

LV480852 additional specifications
ParameterValue
Maximum power dissipation per pole19 W
Poles description1 x 3P switchable
Rated dutyUninterrupted
IK degree of protectionIK07 conforming to EN 50102
IP degree of protectionIP20 conforming to IEC 60529
Mounting modeFixed
Mounting supportBusbars
Mounting locationOne above the other
Mounting positionHorizontal Vertical
Connections - terminalsM8 terminals
Pollution degree3 conforming to IEC 60947
Electrical shock protection classClass II front face
Depth123 mm
Width50 mm
Height405 mm
Electrical durabilityAC-21B: 200 cycles 690 V AC 50/60 Hz AC-22B: 200 cycles 500 V AC 50/60 Hz AC-23B: 200 cycles 415 V AC 50/60 Hz
Mechanical durability1400 cycles
StandardsEN/IEC 60947-1 EN/IEC 60947-3
RangeFuPacT
Fuse sizeNH000 NH00
Visible breakYes
Contact operationSingle-break
Device short nameISFL160
Tightening torque14 N.m
Device applicationEquipment protection, monitoring and control Distribution
Signalling functionSeparated fuse monitor
Number of fuse carriers3
Provision for padlocking3 padlocks
Suitability for isolationYes conforming to EN/IEC 60947-3
Contact position indicatorYes
Ambient air temperature for storage-50...85 °C