Skip to main content
Schneider Electric LV480857

Schneider LV480857 FuPacT ISFL fuse-switch disconnector, 400 A, 1-pole

MPNLV480857
Obsolete

Schneider LV480857 Fupact — now discontinued, supplied from remaining surplus and broker stock.

$464.45Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV480857 key specifications
ParameterValue
Fuse typeDIN
Control typeFuse carriers handle
Product or component typeFuse-switch disconnector
Voltage1000 V AC 50/60 Hz 1000 V DC
[Ue] rated operational voltage690 V AC 50/60 Hz 800 V AC 50/60 Hz AC-20 800 V DC DC-20
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current15 kA for 1 s
[Ie] rated operational currentAC-21B: 400 A at 220/240 V AC 50/60 Hz AC-21B: 400 A at 380/415 V AC 50/60 Hz AC-21B: 400 A at 440/480 V AC 50/60 Hz AC-21B: 400 A at 500 V AC 50/60 Hz AC-21B: 400 A at 660/690 V AC 50/60 Hz AC-22B: 400 A at 220/240 V AC 50/60 Hz AC-22B: 400 A at 380/415 V AC 50/60 Hz AC-22B: 400 A at 440/480 V AC 50/60 Hz AC-22B: 400 A at 500 V AC 50/60 Hz AC-23B: 400 A at 220/240 V AC 50/60 Hz AC-23B: 400 A at 380/415 V AC 50/60 Hz
[Icm] rated short-circuit making capacity30 kA at 690 V
[Iq] breaking capacity with fuses (kA RMS)120 kA at 415 V (AC) 120 kA at 500 V (AC) 120 kA at 690 V (AC)
[Ith] conventional free air thermal current400 A ( 40 °C ) power dissipation per fuse: 34 W
[Ithe] conventional enclosed thermal current400 A at 40 °C, Power dissipation per fuse: 34 W

All specifications

LV480857 additional specifications
ParameterValue
Maximum power dissipation per pole53 W
Poles description1 x 3P switchable
Rated dutyUninterrupted
IK degree of protectionIK07 conforming to EN 50102
IP degree of protectionIP20 conforming to IEC 60529
Mounting modeFixed
Mounting supportBusbars
Mounting locationOne above the other
Mounting positionVertical
Connections - terminalsScrew connection downstream M12 400 A Direct connection upstream 400 A 185 mm
Pollution degree3 conforming to IEC 60947
Electrical shock protection classClass II front face
Depth190 mm
Width100 mm
Height741 mm
Electrical durabilityAC-21B: 200 cycles 690 V AC 50/60 Hz AC-22B: 200 cycles 500 V AC 50/60 Hz AC-23B: 200 cycles 415 V AC 50/60 Hz
Mechanical durability800 cycles
StandardsEN/IEC 60947-1 EN/IEC 60947-3
RangeFuPacT
Fuse sizeNH2
Visible breakYes
Contact operationSingle-break
Device short nameISFL400
Tightening torque40 N.m
Device applicationEquipment protection, monitoring and control Distribution
Signalling functionSeparated fuse monitor
Number of fuse carriers3
Provision for padlocking3 padlocks
Suitability for isolationYes conforming to EN/IEC 60947-3
Contact position indicatorYes
Ambient air temperature for storage-50...85 °C
Ambient air temperature for operation-20...70 °C

Product details

Overview

The LV480857 is a Schneider FuPacT ISFL single-pole fuse-switch disconnector rated for 400 A switching current at 690 V AC, with a 120 kA rated breaking capacity under IEC 60947-3. It provides a visible break and is certified for isolation, making it suitable for equipment protection and safe maintenance isolation in distribution panels.

MPN