Skip to main content
Schneider Electric LV848327

Schneider Electric LV848327

MPNLV848327
Active

Circuit breaker Masterpact MTZ2 40H1 - 4000 A - 4P drawout - w/o Micrologic

$19,903.57Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV848327 key specifications
ParameterValue
Control typePush-button
Performance typeH1 66 kA 415 V AC
Product or component typeCircuit breaker
Voltage1000 V AC 50/60 Hz
[Ue] rated operational voltage690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage12 kV
[Icw] rated short-time withstand current66 kA 0.5 s 66 kA 1 s 66 kA 3 s
Line rated current4000 A 104 °F (40 °C)
[Ics] rated service breaking capacity66 kA 220/415 V AC 50/60 Hz 66 kA 440 V AC 50/60 Hz 66 kA 500/525 V AC 50/60 Hz 66 kA 660/690 V AC 50/60 Hz
[Icm] rated short-circuit making capacity145 kA 220/415 V AC 50/60 Hz 145 kA 440 V AC 50/60 Hz 145 kA 500/525 V AC 50/60 Hz 145 kA 660/690 V AC 50/60 Hz
[Icu] rated ultimate short-circuit breaking capacity66 kA 220/415 V AC 50/60 Hz 66 kA 440 V AC 50/60 Hz 66 kA 500/525 V AC 50/60 Hz 66 kA 660/690 V AC 50/60 Hz
Power dissipation in900 W

All specifications

LV848327 additional specifications
ParameterValue
Poles description4P
IP degree of protectionIP30 conforming to EN 60529
Mounting modeDrawout
Mounting supportRails Base plate
Connection pitch5.9 in (150 mm)
Upside connectionFront Rear
Downside connectionFront Rear
Maximum closing response time70 ms
Pollution degree3 IEC 60947-1
Operating altitude0...6561.68 ft (0...2000 m) without derating 2000...5000 m with derating
DepthDrawout circuit breaker with chassis: 15.9 in (403 mm) Drawout circuit breaker without chassis: 11.8 in (300 mm)
WidthDrawout circuit breaker with chassis: 21.9 in (556 mm) Drawout circuit breaker without chassis: 19.4 in (493 mm)
HeightDrawout circuit breaker with chassis: 17.3 in (439 mm) Drawout circuit breaker without chassis: 11.8 in (300 mm)
Electrical durabilityAC-3 6000 cycles 440/690 V AC 50/60 Hz EN/IEC 60947-3 2500 cycles 690 V AC 50/60 Hz EN/IEC 60947-2 5000 cycles 440 V AC 50/60 Hz EN/IEC 60947-2 AC-23A 2500 cycles 690 V AC 50/60 Hz EN/IEC 60947-3 AC-23A 5000 cycles 440 V AC 50/60 Hz EN/IEC 60947-3
Mechanical durability20000 cycles with periodic preventive maintenance
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12
RangeMasterPacT
Control unitWithout control unit
Sensor rating2000 A 2500 A 3200 A 4000 A
Neutral positionLeft
Device short nameMTZ2 40 H1
Device applicationPower distribution protection
Selectivity categoryCategory B
Maximum breaking time25 ms
Suitability for isolationYes EN/IEC 60947-2
Ambient air temperature for storage-40...185 °F (-40...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)
MPN