Skip to main content
Schneider Electric LX1D2N7 — Contactor & Starter Coils

Schneider Electric LX1D2N7 TeSys Contactor Coil, 415 V AC

MPNLX1D2N7
Obsolete

Schneider Electric TeSys Deca LX1D2N7 contactor coil, 415 V AC 50/60 Hz, for 9 to 18 A contactors, without built-in suppressor module.

$94.53Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LX1D2N7 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1D2
Coil technologyWithout built-in suppressor module
LX1D2N7 — Electrical
ParameterValue
Control circuit voltage [Uc]415 V AC 50/60 Hz
Control circuit typeAC 50/60 Hz
Control circuit voltage limitsOperational: 0.8...1.1 Uc at 50/60 Hz (at <131 °F (55 °C))
Coil resistance (avg.)1938 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)74 H
LX1D2N7 — Power & Thermal
ParameterValue
Inrush power (VA)70 VA 50/60 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power (VA)8 VA 50/60 Hz cos phi 0.3 (at 68 °F (20 °C))

Product details

What this coil does in the panel

The LX1D2N7: It pulls in at 70 VA inrush (cos φ 0.75) and holds at 8 VA (cos φ 0.3) — the inrush-to-hold ratio is typical for AC-operated contactor coils and matters when sizing the control transformer for a multi-contactor panel.

Coil ratings that govern fit

Average DC resistance is 1938 Ω at 20 °C, with a closed-circuit inductance of 74 H — these values let you calculate steady-state current draw for thermal budget in a sealed enclosure. No built-in suppressor module (varistor or RC snubber) is integrated into this coil variant — if your control circuit requires transient suppression, you add it externally at the coil terminals.

Sourcing an obsolete TeSys coil

Schneider has classified the LX1D2N7 as obsolete — it is no longer in active factory production. Available through independent surplus and broker channels; quantities are lot-specific and confirmed at RFQ. No pin-compatible direct successor has been published by the manufacturer for this voltage variant. The part belongs to the TeSys Deca range, which covers contactors in the 9 to 18 A AC-3 duty class — the coil form factor and mounting interface are specific to that frame.