Schneider Electric LX1D6R6

TeSys LX1D6R6 Contactor Coil, 440 V AC 60 Hz, Obsolete

MPNLX1D6R6
Obsolete

Schneider Electric TeSys Deca, LX1D6R6, contactor coil, 440 V AC 60 Hz, for 80 & 95 A contactors.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1D6R6 specifications
ParameterValue
Control circuit typeAC 60 Hz
Product or component typeContactor coil
Coil voltage440 V AC 60 Hz
Control circuit voltage limitsDrop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <131 °F (55 °C))
Inrush power in220 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in22 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Mechanical durability10 Mcycles
RangeTeSys
Category22341-CONTACTOR,D,K,&F ACCESS
Coil technologyWithout built-in suppressor module
Heat dissipation6...10 W 50/60 Hz
Device short nameLX1D6
Average resistance392 Ohm 68 °F (20 °C)
Maximum operating rate3600 cyc/h 140 °F (60 °C)
Inductance of closed circuit19 H
Ambient air temperature for operation23...140 °F (-5...60 °C)

Product details

Part Identity and Fit

The LX1D6R6 is a replacement coil from the Schneider TeSys Deca range, designed for 80 A and 95 A contactors in that family. It is a 440 V AC 60 Hz control circuit coil, the LX1D6 device short name variant, with a 392 Ohm average resistance at 68 °F (20 °C) and an inductance of 19 H when closed. This coil has no built-in suppressor module, so if your panel design requires a snubber or varistor across the coil terminals for noise suppression or to extend the life of the driving PLC output, you will need to add it externally. The heat dissipation runs 6 to 10 W at 50/60 Hz, which should be accounted for in the thermal budget of a tightly packed enclosure.

Control Circuit and Performance

Its operating limits at 60 Hz and below 131 °F (55 °C) are 0.85 to 1.1 Uc for pick-up, and drop-out occurs between 0.3 and 0.6 Uc. Inrush power is 220 VA at 60 Hz with a cos phi of 0.75, while hold-in power drops to 22 VA at 60 Hz with a cos phi of 0.3.

Frequently asked questions

What is the closest alternative to LX1D6R6?

No direct replacement order code is listed by the manufacturer. For a new design, you would need to select a current-production TeSys coil with the same voltage and contactor frame size. Contact us with your contactor model for a cross-reference.

MPN
LX1D6R6