Skip to main content
Schneider Electric LX1G3RKUEN

Schneider LX1G3RKUEN TeSys Contactor Coil, 100-250 V AC/DC

MPNLX1G3RKUEN
Active

Schneider TeSys LX1G3RKUEN contactor coil module, 100–250 V AC/DC control circuit, 3.7 in depth, built-in bidirectional peak limiting.

$357.45Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LX1G3RKUEN key specifications
ParameterValue
Product or component typeContactor coil
Coil voltage100...250 V AC/DC 50/60 Hz
Control circuit voltage limitsOperational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))
Inrush power in840 VA 240 V AC, 60 Hz
Hold-in power consumption in10.6 VA 240 V AC, 60 Hz
Poles description3P
IP degree of protectionIP20 IEC 60529
Connections - terminalsControl circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18
Pollution degree3 IEC 60947-1
Operating altitude9842.52 ft (3000 m) without derating 5000 m with derating factor
Depth3.7 in (93.0 mm)
Width5.5 in (140.0 mm)

All specifications

LX1G3RKUEN additional specifications
ParameterValue
Height6.6 in (167.0 mm)
Mechanical durability5 Mcycles
StandardsEN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1
RangeTeSys
CategoryUS10I1222328
Operating time20...35 ms opening 40...55 ms closing
Coil technologyBuilt-in bidirectional peak limiting
Quantity per set1
Device short nameLX1G
Maximum operating rate600 cyc/mn 140 °F (60 °C)
Electromagnetic compatibilityEMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

The LX1G3RKUEN is a Schneider TeSys contactor coil module — the control-side component that drives the main contactor armature. It accepts a 100…250 V AC/DC control supply (50/60 Hz), with built-in bidirectional peak limiting that suppresses back-EMF and reduces radiated noise on the control wiring. That peak-limiting circuit means you don't need an external snubber for coil suppression, simplifying panel wiring and reducing parts count.

Coil power and thermal headroom

Inrush draws 645 W DC or 840 VA at 240 V AC, 60 Hz, then drops to a 5.9 W DC / 10.6 VA hold-in — a typical ratio for large contactor coils. That inrush transient matters for control transformer sizing: if you're feeding multiple coils from a single 240 VA transformer, sequence the closure to avoid sag. Hold power is modest, so continuous energization doesn't tax the supply. Ambient operating range is -13...140 °F (-25...60 °C). Storage range is -76...176 °F (-60...80 °C). Altitude derating starts above 9842.52 ft (3000 m); at 5000 m a derating factor applies.

Physical fit and termination

IP20 rated (finger-safe, no water ingress). Mechanical durability rated 5 million cycles; maximum operating rate 600 cycles/min at 140 °F (60 °C). For high-cycle applications (e.g., conveyor indexing), that rate is within spec.

Frequently asked questions

What is the depth of the LX1G3RKUEN?

The depth is 3.7 in (93.0 mm). That is the dimension from the mounting base to the front of the module.

Does the LX1G3RKUEN comply with IEC and UL standards?

It is certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. IP20 per IEC 60529.

MPN
LX1G3RKUEN