LX1G4SEHEA key specifications
ParameterValue
Product or component typeContactor coil
Coil voltage48...130 V AC/DC 50/60 Hz
Control circuit voltage limitsOperational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))
Inrush power in380 VA 120 V AC, 60 Hz
Hold-in power consumption in10.1 VA 120 V AC, 60 Hz
Poles description4P
IP degree of protectionIP20 IEC 60529
Connections - terminalsControl circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18
Pollution degree3 IEC 60947-1
Operating altitude9842.52 ft (3000 m) without derating 5000 m with derating factor
Depth3.7 in (93.0 mm)
Width7.3 in (185.0 mm)

All specifications

LX1G4SEHEA additional specifications
ParameterValue
Height6.6 in (167.0 mm)
Mechanical durability5 Mcycles
StandardsEN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1
RangeTeSys
CategoryUS10I1222328
Operating time20...35 ms opening 40...55 ms closing
Coil technologyBuilt-in bidirectional peak limiting
Quantity per set1
Device short nameLX1G
Maximum operating rate600 cyc/mn 140 °F (60 °C)
Electromagnetic compatibilityEMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

The LX1G4SEHEA: Opening time runs 20–35 ms, closing 40–55 ms – fast enough for most motor starts but with a deliberate close that avoids hammering the contacts on the mating power pole. Inrush draw peaks at 295 W DC or 380 VA at 120 V AC; hold-in drops to 5.3 W DC or 10.1 VA at 120 V AC. That low hold power means you can run it off a smaller control transformer without oversizing. Terminals are push-in on the control circuit – 0.2–2.5 mm² solid or stranded, or 0.25–2.5 mm² with ferrules. No screwdriver needed for the coil wiring, and the connection stays solid under vibration.

Frequently asked questions

What is LX1G4SEHEA's listed depth?

Depth is 3.7 in (93.0 mm).

What range does LX1G4SEHEA belong to?

It is part of the TeSys range.

What compliance documentation does this part carry?

It complies with EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1.