Skip to main content
Schneider Electric LXM32MD72N4

Schneider Electric LXM32MD72N4

MPNLXM32MD72N4
Active

Servo Drive, Motion, Lexium 32, 24A, 3PH, 240/480VAC, 6.5kW|Servo Drive, Motion, Lexium 32, 24 Amp, 3-Phase, 240/480 Volt AC, 6.5 kW

$1,009.65Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LXM32MD72N4 key specifications
ParameterValue
Type of cableSingle-strand IEC cable 122 °F (50 °C)) copper 90 °C XLPE/EPR
Protection typeAgainst reverse polarity inputs signal
Type of coolingIntegrated fan
Range of productLexium 32
Control signal typePulse train output (PTO) RS422 <500 kHz <328.08 ft (100 m)
Discrete input typeCapture CAP
Discrete output typeLogic DO)24 V DC
Product or component typeMotion servo drive
Output voltage<= power supply voltage
Supply voltage limits170...264 V 323...528 V
Discrete input voltage24 V DC capture
Discrete output voltage<= 30 V DC

All specifications

LXM32MD72N4 additional specifications
ParameterValue
Supply voltage200...240 V - 15...10 % 380...480 V - 15...10 %
Line current21.1 A 34 % 208 V, with external line choke 1 mH 22.5 A 45 % 400 V, with external line choke 1 mH 19.5 A 55 % 480 V, with external line choke 1 mH 21.9 A 106 % 208 V, without line choke 17.3 A 126 % 400 V, without line choke 14.6 A 129 % 480 V, without line choke
Braking current50 mA
Output current 3s peak72 A 208 V 5 s 72 A 480 V 5 s
Maximum leakage current30 mA
Continuous output current24 A 8 kHz
Nominal power5 kW 208 V 8 kHz 7 kW 400 V 7 kW 480 V 8 kHz
Continuous power6500 W 208 V 13000 W 400 V 13000 W 480 V
Supply frequency50/60 Hz - 5...5 %
Network frequency47.5...63 Hz
Switching frequency8 kHz
PhasesThree phase
IP degree of protectionIP20 conforming to EN/IEC 60529
Communication interfaceModbus TCP, with separated communication card CANopen, with separated communication card CANmotion, with separated communication card Ethernet/IP, with separated communication card EtherCAT, with separated communication card Profibus, with separated communication card Profinet, with separated communication card Analog I/O, with separated communication card Digital I/O, Integrated
Electrical connectionTerminal 3 mm², AWG 12 CN8)
Response time<= 5 ms compliment of STO_A, compliment of STO_B
Response time on output250 µs DO)discrete
EMC filterIntegrated
Pollution degree2 EN/IEC 61800-5-1
Shock resistance15 gn 11 ms EN/IEC 60028-2-27
Relative humidityClass 3K3 (5 to 85 %) without condensation IEC 60721-3-3
Operating altitude<= 3280.84 ft (1000 m) without derating
Vibration resistance1 gn (f= 13...150 Hz) conforming to EN/IEC 60068-2-6
Depth9.3 in (237 mm)
Width4.3 in (108 mm)
Height10.6 in (270 mm)
StandardsEN/IEC 61800-3
MarkingCE
CategoryUS1PC5118261
Status LED1 LED (Red) servo drive voltage
Safety levelSIL 3 EN/IEC 61508
Safety functionSTO (safe torque off), Integrated
Device short nameLXM32M
Sampling duration0.25 ms
Tightening torqueCN8 4.4 lbf.in (0.5 N.m)
Operating positionVertical +/- 10 degree
Contact bounce time<= 1 ms compliment of STO_A, compliment of STO_B
Format of the driveBook
Signalling functionDisplay of faults 7 segments
Discrete input logicPositive compliment of STO_A, compliment of STO_B)< 5 V > 15 V EN/IEC 61131-2 type 1
Electrical isolationBetween power and control
Overvoltage categoryIII
Discrete input number2 capture
Discrete output logicPositive or negative DO)EN/IEC 61131-2
Discrete output number3
Environmental characteristicClasses 3C1 conforming to IEC 60721-3-3
Electromagnetic compatibilityConducted EMC, class A group 1 EN 55011
Ambient air temperature for storage-13...158 °F (-25...70 °C)
Ambient air temperature for operation32...122 °F (0...50 °C) UL
MPN
LXM32MD72N4