Skip to main content
Schneider Electric M9D14625

Schneider Electric M9D14625

MPNM9D14625
Obsolete

Residual current breaker with overcur. prot. (RCBO), Multi9 N40 Vigi, 1P+N, 25A, C curve, 6000A/6kA, AC type, 300mA

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

M9D14625 key specifications
ParameterValue
Control typeToggle
Network typeAC
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Voltage400 V AC 50 Hz EN/IEC 60947-2
[Ue] rated operational voltage240 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kVEN/IEC 60947-2
Surge current250 A
Breaking capacity6 kA Icu 240 V AC 50 Hz EN/IEC 60947-2 6000 A Icn 240 V AC 50 Hz EN/IEC 61009-1
Line rated current25 A 122 °F (50 °C) EN/IEC 60947-2
Residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity4.5 kA 75 % EN/IEC 60947-2 - 240 V AC 50 Hz
Network frequency50 Hz

All specifications

M9D14625 additional specifications
ParameterValue
Poles description1P + N
Number of protected poles1
Utilisation categoryCategory A EN/IEC 60947-2
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Mounting modeClip-on
Mounting supportDIN rail
Connection pitch0.4 in (9 mm) between phase and neutral
Wire stripping length0.5 in (13 mm) for top or bottom connection
Connections - terminalsTunnel type terminal top or bottom) 0.001...0.02 in² (0.75...16 mm²) - rigid Tunnel type terminal top or bottom) 0.0005...0.02 in² (0.33...10 mm²) - flexible Tunnel type terminal top or bottom) 0.0005...0.02 in² (0.33...10 mm²) - flexible with ferrule
Pollution degree3 EN/IEC 60947-2
Relative humidity95 % 131 °F (55 °C)
ColorGray
Depth2.8 in (70 mm)
Width1.4 in (36 mm)
Height3.2 in (81 mm)
Electrical durability10000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 61009-1 EN/IEC 60947-2
RangeMulti9
CategoryUS10DE200908
Curve codeC
9 mm pitches4
Tropicalisation2 IEC 60068-1
Limitation class3 EN/IEC 61009-1
Local signallingON/OFF indication Fault indication
Neutral positionLeft
Device short nameN40 Vigi
Tightening torque17.7 lbf.in (2 N.m) top or bottom
Device applicationDistribution
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 % AC
Earth-leakage protectionIntegrated
Provision for padlockingPadlockable
Earth-leakage sensitivity300 mA
Suitability for isolationYes EN/IEC 60947-2
Contact position indicatorYes
Electromagnetic compatibility8/20 µs impulse withstand, 250 A
Earth-leakage protection classType AC
Rated breaking and making capacityIdm 4500 A 240 V AC 50 Hz EN/IEC 61009-1
Ambient air temperature for storage-22...158 °F (-30...70 °C)
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation23...140 °F (-5...60 °C)
MPN
M9D14625