Skip to main content
Schneider Electric METSECT5MA015

Schneider Electric METSECT5MA015 PowerLogic CT, 150/5, Obsol

MPNMETSECT5MA015
Obsolete

Schneider Electric PowerLogic series, solid-core current transformer, 150/5 A ratio, accuracy class 0.5 at 3 VA, obsolete lifecycle.

$24.13Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

METSECT5MA015 key specifications
ParameterValue
Current transformer typeTropicalised for busbar and cable Solid core
Product or component typeCurrent transformer
Dynamic withstand current2.5 Ith
Voltage3 kV 50 Hz for 1 minute
[Ue] rated operational voltage< 720 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage3 kV
Secondary current5 A
Current150 A
Current transformer ratio150/5
[Ith] conventional free air thermal current9 kA
IP degree of protectionIP20
Mounting modeInsulated locking screw

All specifications

METSECT5MA015 additional specifications
ParameterValue
Mounting supportDIN rail Mounting plate Busbar
Cable outer diameter27 mm
Relative humidity0...95 %
DepthFrame : 43 mm Total : 63 mm
WidthOutside: 56 mm
HeightOutside: 80 mm
StandardsVDE 0414 IEC 61869-2
RangePowerLogic
SealingWithout
Diameter27 mm
AccuracyClass 0.5 at 3 VA Class 1 at 5 VA
Opening of bars32.5 x 10.5 25.5 x 15.5
Maximum safety factor5
Electrical insulation classClass B
Ambient air temperature for operation-25...60 °C

Product details

The METSECT5MA015 is an obsolete solid-core current transformer from the Schneider Electric PowerLogic range, with a 150/5 A ratio and accuracy class 0.5 at 3 VA. This CT is no longer in production; sourcing is through independent surplus and broker channels. Rated for systems up to 720 V AC at 50/60 Hz, with an insulation voltage rating of 3 kV for 1 minute (Ui). Mounting options include DIN rail, mounting plate, or busbar. The busbar opening accepts two sizes: 32.5 x 10.5 mm and 25.5 x 15.5 mm. Cable entry diameter is 27 mm.

Accuracy and thermal withstand

Duality accuracy spec: class 0.5 at 3 VA burden, class 1 at 5 VA. For metering applications needing ±0.5% error at rated current, stay at or below 3 VA burden. The CT complies with IEC 61869-2 and VDE 0414. Insulation class B, IP20 finger-safe enclosure. Rated impulse withstand voltage (Uimp) 3 kV.

Frequently asked questions

What are the key ratings of this CT?

150/5 A ratio, accuracy class 0.5 at 3 VA, conventional thermal current (Ith) 9 kA, dynamic withstand 2.5 Ith, rated operational voltage up to 720 V AC.

How can I source this obsolete CT?

This part is not available new from the manufacturer. Submit an RFQ; our team can check surplus and new-old-stock availability from independent channels.

MPN