MGN60530 C60N Miniature Circuit Breaker, 1 A D Curve, 3P

MPNMGN60530
Obsolete

Schneider Electric Multi9 C60N series, MGN60530 miniature circuit breaker, 3-pole, 1 A rated current, D curve, 20 kA Icu at 240 V AC, thermal-magnetic trip, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60530 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60530 — Ratings
ParameterValue
Rated current (In)1 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60530 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60530 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN60530 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60530 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric MGN60530 is a C60N miniature circuit breaker from the Multi9 range — a 3-pole, 1 A rated device with a D curve, built to EN/IEC 60947-2 for distribution duty. It breaks 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, so it handles high inrush loads like motor circuits or transformer primaries where the D curve's 12 x In magnetic trip (+/- 20%) avoids nuisance trips on startup.

IP20 finger-safe for panel interiors.

The 1 A rating at 50 °C (EN/IEC 60947-2) governs continuous load — this breaker protects a 1 A branch, not a motor starter. The D curve's 12 x In magnetic trip (12 A nominal, +/- 20%) means it tolerates short-duration inrush without tripping, making it a fit for control transformers, solenoid banks, or small motor loads where a C curve would nuisance-trip. Service breaking capacity (Ics) is 75% of Icu: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V — enough for most industrial panel fault levels. Electrical durability is 10,000 cycles; mechanical, 20,000 cycles.

Frequently asked questions

Where can I buy the MGN60530 and get a price?

The MGN60530 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current availability and pricing — confirmed at quote time.

What is the MGN60530's breaking capacity at different voltages?

It breaks 20 kA Icu at 240 V AC, 10 kA at 415 V AC, and 6 kA at 440 V AC, all phase-to-phase per EN/IEC 60947-2. Service breaking capacity (Ics) is 75% of those values.

What does the D curve mean on this breaker?

The D curve means magnetic tripping occurs at 12 x In (+/- 20%), so this 1 A breaker trips magnetically between roughly 9.6 A and 14.4 A. It's designed for high-inrush loads like motors and transformers where a C curve would trip on startup.

What compliance documentation does Schneider provide for the MGN60530?

The MGN60530 is certified to EN/IEC 60947-2 and carries IP20 protection. It is suitable for isolation per that standard. For specific RoHS, REACH, or UL documentation, request the compliance pack with your RFQ.

MPN