Schneider Electric MGN60532 — Miniature Circuit Breakers (MCB)

MGN60532 C60N MCB, 3P D-curve 3A, 20kA/240V

MPNMGN60532
Obsolete

Schneider Electric Multi9 C60N series, MGN60532 miniature circuit breaker, 3-pole, D-curve, 3 A rated current, 20 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60532 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60532 — Ratings
ParameterValue
Rated current (In)3 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60532 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60532 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN60532 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60532 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60532 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, 3-pole, D-curve, rated 3 A at 50 °C per EN/IEC 60947-2. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — all conforming to EN/IEC 60947-2. Rated service breaking capacity (Ics) is 75 % of Icu: 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. That's the level the breaker can clear and still be reused — important for coordination studies on distribution panels.

Tightening torque 2 N·m on the power circuit; strip length 14 mm. IP20 finger-safe protection. Dimensions: 81 mm high, 54 mm wide (6 modules), 73 mm deep. The 73 mm depth is the body depth behind the panel — relevant when sizing enclosure depth or clearance for wiring ducts.

Rated for isolation (suitability for isolation: Yes per EN/IEC 60947-2), with a contact position indicator and ON/OFF local signalling. Electrical durability 10,000 cycles, mechanical 20,000 cycles.

Frequently asked questions

What is the breaking capacity of MGN60532?

20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2. Service breaking capacity (Ics) is 75 % of those values.

What does the D-curve mean on this breaker?

The D-curve magnetic trip is 12 x In ±20 %, designed for loads with high inrush current such as motors, transformers, or welding equipment. It avoids nuisance tripping on startup surges.

What compliance documentation does Schneider provide for MGN60532?

The breaker is certified to EN/IEC 60947-2, pollution degree 3. It carries suitability for isolation marking and contact position indication. Specific RoHS/REACH/UL documentation is available from the manufacturer upon request.

Where can I buy MGN60532 and how is it quoted?

The MGN60532 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN