Skip to main content
Schneider Electric MGN60544 — Miniature Circuit Breakers (MCB)

MGN60544 C60N MCB, 4P D-Curve 2A, 20kA Breaking Capacity

MPNMGN60544
Obsolete

Schneider Electric C60N Multi9 series, MGN60544, 4-pole D-curve miniature circuit breaker, rated 2 A at 50 °C, 20 kA Icu at 240 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60544 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60544 — Ratings
ParameterValue
Rated current (In)2 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60544 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60544 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60544 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60544 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Rated 2 A at 50 °C per EN/IEC 60947-2, this 4-pole breaker protects all three phases and neutral in a single module. The 20 kA Icu at 240 V AC phase-to-phase gives it the interrupting capacity to handle high-fault-current points in a panel; at 415 V the rating drops to 10 kA Icu, and at 440 V to 6 kA Icu — so the voltage at the fault point governs whether this breaker holds coordination with the upstream device. The 75 % Ics rating (15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V) tells you it can be reclosed after clearing a fault at those levels and still carry rated current — useful for a panel where you want to restore power without swapping the breaker after a downstream short.

The 72 mm width (8 x 9 mm pitches) and 81 mm height fit a standard modular enclosure grid; depth of 73 mm leaves room for wiring behind the rail.

Frequently asked questions

What is MGN60544 used for?

It is a 4-pole D-curve miniature circuit breaker rated 2 A at 50 °C, used for protecting motor circuits, transformers, and other inductive loads in distribution boards where high inrush current is expected.

Where can I buy MGN60544?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What standards does MGN60544 comply with?

It is certified to EN/IEC 60947-2, pollution degree 3, and is suitable for isolation per that standard.