Schneider Electric MGN60550 — Miniature Circuit Breakers (MCB)

MGN60550 C60N MCB, 20A 4P D-Curve, 20kA at 240V

MPNMGN60550
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60550, 4-pole, 20 A rated, D-curve, 20 kA breaking capacity at 240 V AC, EN/IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60550 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60550 — Ratings
ParameterValue
Rated current (In)20 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60550 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60550 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60550 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60550 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60550 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2 with a D-curve and 4 protected poles.

The C60N delivers 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — all per EN/IEC 60947-2. The corresponding Ics (service breaking capacity) is 75 % of Icu at each voltage level: 15 kA at 240 V, 7.5 kA at 415 V, and 4.5 kA at 440 V. That Ics margin means the breaker can be reclosed after clearing a fault at those levels without immediate replacement, which matters for selectivity coordination in a distribution board.

Trip curve and application

The D-curve magnetic trip is set at 12 x In ±20 %, so the breaker holds through motor inrush and transformer energization without nuisance tripping. Thermal-magnetic trip technology covers both overload and short-circuit protection. Rated operational voltage is 440 V AC phase-to-phase, 240 V phase-to-neutral.

The 4-pole unit occupies 8 x 9 mm pitches (72 mm wide). Pollution degree 3 per EN/IEC 60947-2, IP20 finger-safe terminals.

Frequently asked questions

What is the breaking capacity of MGN60550?

The MGN60550 has a breaking capacity (Icu) of 20 kA at 240 V AC, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of Icu at each voltage.

What is the D-curve magnetic trip setting?

The D-curve magnetic trip is set at 12 x In ±20 %, suitable for loads with high inrush current such as motors and transformers.

What standards does MGN60550 comply with?

The MGN60550 complies with EN/IEC 60947-2, including pollution degree 3 and utilization category A. It is also suitable for isolation per that standard.