Schneider Electric MGN60639 — Miniature Circuit Breakers (MCB)

MGN60639 C60H MCB, 3P 10A Curve C, 30 kA, Multi9

MPNMGN60639
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, 3-pole, 10 A, curve C, 30 kA Icu at 240 V AC, EN/IEC 60947-2, IP20, 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60639 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60639 — Ratings
ParameterValue
Rated current (In)10 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 40 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60639 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60639 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN60639 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60639 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Integrator note — C60H 3P 10 A curve C

The MGN60639 is a C60H miniature circuit-breaker from the Multi9 range, rated 10 A at 50 °C per EN/IEC 60947-2, with a C curve (magnetic trip at 8.5 x In ±20 %). Three protected poles, thermal-magnetic trip unit, suitable for isolation. The Ics (service breaking capacity) is 50 % of Icu at AC voltages — 15 kA at 240 V AC, 7.5 kA at 415 V AC, 5 kA at 440 V AC — and 40 kA (100 %) at 125 V DC. That DC rating makes it a candidate for battery-bank or UPS output protection where high interrupting capacity is needed.

Panel integration — DIN rail and wiring

Occupies 6 x 9 mm pitches (54 mm wide). Comb busbar compatible top or bottom. IP20 finger-safe for enclosed panel use.

Listed as current-production lifecycle stage. Fully compliant with EN/IEC 60947-2 (Category A). Electrical endurance rated 10,000 cycles, mechanical 20,000 cycles. Ambient operating range -30…70 °C, storage -40…80 °C. Earth-leakage protection requires a separate Vigi block — not integrated.

Frequently asked questions

What is the breaking capacity of MGN60639 at 240 V AC?

30 kA Icu at 240 V AC 50/60 Hz phase-to-phase per EN/IEC 60947-2. The Ics at that voltage is 15 kA (50 %).

What is the closest alternative to MGN60639 in the same family?

Within the C60 range, the standard C60 (non-H) offers lower breaking capacity — typically 10 kA or 15 kA at 240 V AC — versus the C60H's 30 kA. The C60H is the high-interrupting variant; if your fault level is below 15 kA, a C60 may suffice, but verify coordination with your upstream device.

Where can I buy MGN60639 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

MPN