Schneider Electric MGN60648 — Miniature Circuit Breakers (MCB)

Schneider Electric MGN60648 C60H MCB, 2A C-Curve 4P, 30kA

MPNMGN60648
Obsolete

Schneider Electric Multi9 C60H series, MGN60648 miniature circuit breaker, 4-pole, 2 A rated current, C-curve, 30 kA Icu at 240 V AC, EN/IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60648 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60648 — Ratings
ParameterValue
Rated current (In)2 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC
Rated operational voltage (Ue)440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60648 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60648 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60648 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60648 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60648 is a Schneider Electric C60H miniature circuit breaker from the Multi9 range, rated 2 A at 50 °C with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20 %). The 4-pole configuration with 4 protected poles makes it a straight choice for three-phase plus neutral distribution circuits where you need coordinated overcurrent and short-circuit protection on all poles. That is a high-capacity rating for a 2 A frame, so it is sized for installations with substantial upstream fault current, not a lightly braked subpanel. That is a real-world durability figure: if you are coordinating selectivity in a panel where a downstream fault might hit 15 kA, this breaker survives the event and stays in service. At 250 V DC the Icu jumps to 50 kA, which is unusually high for a DC-rated MCB — it handles the arc extinction challenge of DC circuits where there is no natural zero-crossing. Rated operational voltage spans 240 V AC phase-to-phase, 415 V AC phase-to-phase, 440 V AC, and 250 V DC.

The 72 mm width (8 x 9 mm pitches) for a 4-pole breaker is the expected footprint; it occupies four module spaces. The IP20 finger-safe terminals are fine for enclosed distribution boards; no washdown rating here. The toggle control with ON/OFF indication gives a clear visual state for commissioning and troubleshooting.

The C60H series is the high-breaking-capacity variant of the C60 family. If you are auditing an installed base or filling a spare, the Multi9 range is a well-established platform with broad comb-busbar and distribution-block compatibility (top or bottom feed). The separate earth-leakage protection block option means you can add RCD functionality without replacing the breaker.

Frequently asked questions

What is the breaking capacity of MGN60648?

The MGN60648 has a rated breaking capacity (Icu) of 30 kA at 240 V AC phase-to-phase, 15 kA at 415 V AC, 10 kA at 440 V AC, and 50 kA at 250 V DC, all per EN/IEC 60947-2.

What is the rated current and curve of MGN60648?

Rated current is 2 A at 50 °C with a C-curve trip characteristic (magnetic tripping at 8.5 x In ±20 %).

Where can I buy MGN60648 and how is it quoted?

The MGN60648 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does MGN60648 comply with?

It complies with EN/IEC 60947-2, utilisation category A, and is suitable for isolation per that standard.