Skip to main content
Schneider Electric MGN60649 — Miniature Circuit Breakers (MCB)

MGN60649 C60H 4P MCB, 3 A C-Curve, 50 kA DC Breaking

MPNMGN60649
Obsolete

Schneider Electric Multi9 C60H series, MGN60649, 4-pole miniature circuit breaker, 3 A rated current, C-curve, 50 kA Icu at 250 V DC, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60649 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60649 — Ratings
ParameterValue
Rated current (In)3 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC
Rated operational voltage (Ue)440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60649 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60649 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60649 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60649 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60649 is a Schneider Electric C60H miniature circuit breaker from the Multi9 range, built for DC distribution panels where a 4-pole, 3 A C-curve thermal-magnetic trip is needed. What sets this one apart is the DC-side breaking capacity: 50 kA Icu at 250 V DC, which is the number you care about when protecting battery banks or rectifier outputs — the AC ratings (30 kA at 240 V, 15 kA at 415 V) are there for dual-use circuits but the DC figure is the headline. It snaps onto a 35 mm DIN rail, occupies 8 modules (72 mm wide), and the C-curve means magnetic trip between 5 and 10 times rated current — standard for general distribution and moderate inrush loads like small transformers or capacitor banks.

The service breaking capacity (Ics) at the same voltage is also 50 kA (100 %), meaning it can clear that fault level repeatedly without degrading, which is rare for DC breakers and gives you real selectivity headroom in a string of panels. On the AC side, the Ics drops to 50 % of Icu (15 kA at 240 V, 7.5 kA at 415 V), so if your circuit sees repeated AC faults near the maximum, plan for replacement after the first event. If your panel ambient runs cooler, you get some headroom; above 50 °C, derate per the standard thermal curve. The magnetic trip threshold is 8.5 x In ±20 %, so it holds through motor inrush and capacitor charging currents up to about 25 A peak before instantaneously opening.

Panel integration

The 4-pole body takes 8 module pitches (72 mm wide, 81 mm tall, 73 mm deep). The toggle actuator gives local ON/OFF indication, and the contact position indicator confirms isolation visually — important for lockout/tagout. Comb busbars and distribution blocks can feed from top or bottom. Earth-leakage protection requires a separate Vigi block — not integrated.

MPN