Skip to main content
Schneider Electric MGN60657 — Miniature Circuit Breakers (MCB)

Schneider Electric MGN60657 C60H MCB, 40A 4P C-Curve, 30 kA

MPNMGN60657
Obsolete

Schneider Electric C60H Multi9 miniature circuit breaker, MGN60657, 40 A, 4-pole, C-curve, 30 kA Icu at 240 V AC, thermal-magnetic trip, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60657 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60657 — Ratings
ParameterValue
Rated current (In)40 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 50 kA Icu at 250 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 250 V DC
Rated operational voltage (Ue)440 V AC 50/60 Hz 250 V DC 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60657 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60657 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60657 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60657 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric MGN60657 is a C60H miniature circuit breaker from the Multi9 range, rated 40 A at 50 °C with a C-curve (magnetic trip at 8.5 x In ±20 %). It is a 4-pole device (4 protected poles) with a thermal-magnetic trip unit, designed for distribution applications per EN/IEC 60947-2. At 415 V AC the breaking capacity is 15 kA Icu, and at 440 V AC it drops to 10 kA Icu; at 250 V DC it holds 50 kA Icu. The Ics (service breaking capacity) is 50 % of Icu at AC voltages (15 kA at 240 V, 7.5 kA at 415 V, 5 kA at 440 V) and 100 % at 250 V DC (50 kA). This MCB is suitable for isolation (marked with the open-knife symbol) and carries a contact position indicator for visual confirmation of open/closed state.

The 72 mm width (8 x 9 mm pitches) and 81 mm height fit standard distribution board cutouts; depth is 73 mm. Tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors (with or without cable end), with a stripping length of 14 mm and a tightening torque of 3.5 N·m. IP20 finger-safe protection is standard for the enclosure. The MCB is compatible with comb busbars and distribution blocks on top or bottom, and an optional separate earth-leakage protection block can be added.

The MCB carries 10,000 electrical cycles and 20,000 mechanical cycles durability. Compliance documentation (declaration of conformity, CE marking) is available through the standard Schneider Electric documentation portal.

Frequently asked questions

What is the breaking capacity of MGN60657 at 240 V AC?

30 kA Icu at 240 V AC phase-to-phase per EN/IEC 60947-2, with an Ics of 15 kA (50 %).

What is the closest alternative to MGN60657 in the same family?

Within the C60H series, the 4-pole 40 A C-curve variant is the MGN60657 itself. A functionally similar part with a different breaking capacity (e.g., C60N at lower kA) or a different curve (B or D) would be a different order code — verify the required short-circuit rating and trip characteristic before substituting.

Where can I buy MGN60657 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
MGN60657