Skip to main content
Schneider Electric MGN60888 — Miniature Circuit Breakers (MCB)

MGN60888 C60N MCB, 3P, 1 A, C Curve, 20 kA Icu

MPNMGN60888
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60888, 3 poles, 1 A rated current, C curve, 20 kA Icu at 240 V AC, thermal-magnetic trip, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60888 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60888 — Ratings
ParameterValue
Rated current (In)1 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60888 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60888 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN60888 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60888 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60888 is a 3-pole C60N miniature circuit-breaker from the Multi9 range, rated 1 A at 50 °C per EN/IEC 60947-2. The 20 kA Icu at 240 V AC phase-to-phase gives headroom for high-fault panels; at 415 V AC the breaking capacity is 10 kA Icu, and at 440 V AC it drops to 6 kA Icu — so the voltage class of your supply determines the available fault-clearing capability. This is a Category A breaker (no intentional short-time delay), so it's suited for branch-circuit protection where selectivity with upstream devices relies on current-limiting performance rather than time grading. The thermal-magnetic trip unit provides overload protection via the bimetal element and short-circuit protection via the solenoid — no electronic adjustment, so set it and forget it.

The 3-pole body occupies 6 x 9 mm pitches (54 mm wide), 81 mm tall, 73 mm deep — standard footprint for a Multi9 C60N. IP20 finger-safe terminals suit enclosed panel use.

Frequently asked questions

What is MGN60888's breaking capacity at different voltages?

The MGN60888 has a breaking capacity (Icu) of 20 kA at 240 V AC, 10 kA at 415 V AC, and 6 kA at 440 V AC, all phase-to-phase per EN/IEC 60947-2. The Ics (service breaking capacity) is 75% of Icu at each voltage level.

MPN
MGN60888