Skip to main content
Schneider Electric MGN60895 — Miniature Circuit Breakers (MCB)

MGN60895 C60N MCB, 3P, 20 A, Curve C, 10 kA at 415 V

MPNMGN60895
Obsolete

Schneider Electric Multi9 C60 series, C60N miniature circuit breaker, MGN60895, 3-pole, 20 A, curve C, 10 kA Icu at 415 V AC, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60895 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60895 — Ratings
ParameterValue
Rated current (In)20 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60895 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60895 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN60895 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60895 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60895 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, configured as a 3-pole, 20 A unit with a C trip curve. It's designed for distribution board duty and snaps onto 35 mm symmetrical DIN rail, making it a standard fit for panel builds where the C60 family is already specced. Rated 20 A at 50 °C per EN/IEC 60947-2, with a breaking capacity of 10 kA Icu at 415 V AC phase-to-phase. That's the number to check for fault-clearing capability on your supply side — at 240 V it rises to 20 kA Icu. Curve C means magnetic tripping occurs between 5 and 10 times rated current; the datasheet fixes it at 8.5 x In ± 20 %.

This is a 3-pole breaker for DC network applications, so confirm your system voltage and polarity requirements against the rated operational voltage of 440 V AC / 240 V AC phase-to-phase.

Installation and compliance notes

Mounts fixed on 35 mm DIN rail. Strip length 14 mm. The tunnel-type terminals are compatible with comb busbars top or bottom, which speeds up panel wiring when feeding multiple breakers. Pollution degree 3 per EN/IEC 60947-2 means it's rated for conductive pollution in industrial atmospheres. Mechanical durability rated at 20,000 cycles, electrical durability at 10,000 cycles. Ambient operating range -30…70 °C, storage -40…80 °C. The ON/OFF indication on the toggle and contact position indicator give visual confirmation of breaker state without needing to meter the load side.

Frequently asked questions

What is the breaking capacity of MGN60895 at 415 V?

The MGN60895 has a breaking capacity of 10 kA Icu at 415 V AC phase-to-phase. The service breaking capacity Ics at that voltage is 7.5 kA (75 % of Icu).

What does curve C mean on this breaker?

Curve C on the MGN60895 means the magnetic trip is set at 8.5 x In ± 20 %, so it trips magnetically between roughly 7 and 10 times rated current. This suits moderate inrush loads like small motors or lighting circuits.

Where can I buy MGN60895 and how is it quoted?

The MGN60895 is sourced to order against an RFQ. Send the line item and we'll confirm availability and current pricing at quote time — no stock figures or lead-time numbers on the page.

What compliance documentation does MGN60895 carry?

The MGN60895 is certified to EN/IEC 60947-2 and carries pollution degree 3 rating. For RoHS, REACH, UL, and other compliance documentation, the manufacturer provides these per lot — request them with your RFQ.

MPN
MGN60895