MGN60904 C60N MCB 4P C-Curve 4A 20kA, Multi9

MPNMGN60904
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60904, 4-pole, C-curve, 4 A rated current, 20 kA breaking capacity at 240 V AC, EN/IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60904 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60904 — Ratings
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60904 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60904 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60904 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60904 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60904 is a 4-pole C60N miniature circuit-breaker from the Multi9 range, rated 4 A with a C trip curve. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. Rated operational voltage is 440 V AC 50/60 Hz, so it covers standard 400/415 V three-phase panels. The thermal-magnetic trip unit handles overloads thermally and short-circuits magnetically — no electronics to fail.

Mounting and integration — DIN rail, 8-pitch footprint

The 4-pole body takes 8 x 9 mm pitches (72 mm wide), so plan for 72 mm of rail space plus finger-duct clearance on each side. Strip length 14 mm. IP20 rated — suitable for enclosed panel use only, not washdown or outdoor. Ambient operating range -30…70 °C, storage -40…80 °C.

Frequently asked questions

Where can I buy MGN60904?

The MGN60904 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of MGN60904?

20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2.

What is the closest alternative to MGN60904 in the C60 family?

Within the C60 range, the main variant is the C60H (higher breaking capacity — 25 kA at 415 V) versus the C60N here at 10 kA at 415 V. The C60L offers 15 kA at 415 V. All share the same 4-pole C-curve 4 A thermal-magnetic trip and DIN-rail footprint, so the choice is driven by the required fault level at the installation point.

What compliance documentation does Schneider provide for MGN60904?

The MGN60904 is certified to EN/IEC 60947-2. Standard documentation includes the manufacturer's declaration of conformity and the product datasheet. Specific RoHS or REACH declarations are available from Schneider Electric upon request.

MPN