Skip to main content
Schneider Electric MGN60913 — Miniature Circuit Breakers (MCB)

MGN60913 C60N MCB, 4P, 63 A, C Curve, 20 kA

MPNMGN60913
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60913, 4-pole, 63 A, C curve, 20 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN60913 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN60913 — Ratings
ParameterValue
Rated current (In)63 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN60913 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8.5 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN60913 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN60913 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN60913 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN60913 is a C60N miniature circuit breaker from the Multi9 range, rated 63 A at 50 °C per EN/IEC 60947-2. The 4-pole configuration protects all phases plus neutral in a single 72 mm wide package, occupying 8 x 9 mm pitch spaces on a 35 mm DIN rail. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, derating to 10 kA at 415 V and 6 kA at 440 V. The service breaking capacity Ics is 75 % of those values — 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V. That means after clearing a fault at the Ics level, the breaker remains functional for continued service, not just a one-shot isolation event. For a distribution board with a 22 kA prospective fault current upstream, this breaker needs a current-limiting upstream device to stay within its rating.

The 72 mm width (8 x 9 mm pitches) fits standard distribution board grids. Tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors (with or without ferrules); strip length is 14 mm, torque to 3.5 N·m. The 63 A rating is at 50 °C; expect derating above that ambient. The toggle provides local ON/OFF indication and a contact position indicator for visual confirmation of isolation state.

Frequently asked questions

What is the breaking capacity of MGN60913?

The MGN60913 has a breaking capacity of 20 kA Icu at 240 V AC, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2. The service breaking capacity Ics is 75 % of those values.

What terminals does MGN60913 accept?

Tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors, with or without ferrules. Strip length is 14 mm, tightening torque 3.5 N·m.

Where can I buy MGN60913?

The MGN60913 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
MGN60913