MGN61651 C60PV-DC MCB, 2P 16A 650V DC C-Curve

MPNMGN61651
Obsolete

Schneider Electric C60PV-DC, miniature circuit breaker, 2-pole, 16 A, 650 V DC, C-curve, 1.5 kA Icu.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61651 key specifications
ParameterValue
Control typeToggle
Network typeDC
Range of productC60
Product or component typeMiniature circuit-breaker
Voltage drop656 mV 41 mOhm 10.496 W 16 A
Voltage1000 V DC
[Ue] rated operational voltage650 V DC
[Uimp] rated impulse withstand voltage6 kV
Breaking capacity1.5 kA Icu
Current16 A
[Ics] rated service breaking capacity1.5 kA 100 %
Poles description2P

All specifications

MGN61651 additional specifications
ParameterValue
Number of protected poles2
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Wire stripping length14 mm
Pollution degree2
Relative humidity95 % at 55 °C
Depth77.4 mm
Width72 mm
ColorGrey
Height132.7 mm
Electrical durability1500 cycles L/R = 2 ms
Mechanical durability20000 cycles
StandardsEN/IEC 60947-2
Curve codeC
9 mm pitches8
Device short nameC60PV-DC
Tightening torque2.5 N.m
Compatibility codeC60PV-DC
Magnetic tripping limit8.5 x In
Suitability for isolationYes conforming to EN/IEC 60947-2
Contact position indicatorYes
Locking options descriptionPadlocking in OFF position
Ambient air temperature for storage-40...85 °C
Ambient air temperature for operation-25...70 °C

Product details

DC-rated MCB for photovoltaic and battery strings

The MGN61651 is a C60PV-DC miniature circuit breaker from Schneider Electric, designed specifically for DC circuits up to 650 V. The 100 % Ics rating (same 1.5 kA) means it can reclose after clearing a fault at full rated capacity, which matters for service continuity in solar arrays.

What ships in the box — kit completeness

The MGN61651 ships as a single 2-pole breaker, 72 mm wide (8 x 9 mm pitches), with a toggle actuator and a padlocking provision in the OFF position. It mounts directly onto 35 mm symmetrical DIN rail — no adapter plate needed. The wire terminals accept 14 mm strip length, torqued to 2.5 N·m. That is the full carton contents; no separate accessories are required for basic installation. No auxiliary contact block or shunt trip is included — those are separate order codes if needed.

Frequently asked questions

Where can I buy MGN61651?

The MGN61651 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.