Schneider Electric MGP0403XE2 — Miniature Circuit Breakers (MCB)

MGP0403XE2 PowerPacT 4 Circuit Breaker, 40 A, MicroLogic 2.2

MPNMGP0403XE2
Obsolete

Schneider Electric PowerPacT 4, panel-mount circuit breaker, MGP0403XE2, 3P, 40 A at 40 °C, MicroLogic 2.2 electronic trip unit, 36 kA Icu at 415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0403XE2 — Identification
ParameterValue
Product range (series)PowerPacT 4
Product/component typeCircuit breaker
Device applicationDistribution
MGP0403XE2 — Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V
Rated impulse withstand voltage (Uimp)8 kV
Utilisation categoryCategory A
MGP0403XE2 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to BS EN 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In
Mechanical durability (cycles)50000 cycles
MGP0403XE2 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
MGP0403XE2 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity36 kA Icu at 415 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity36 kA at 415 V AC 50/60 Hz
MGP0403XE2 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range18...40 A
Trip unit protection functionsLSoI

Product details

The MGP0403XE2 is a Schneider Electric PowerPacT 4 panel-mount circuit breaker with a MicroLogic 2.2 electronic trip unit, rated 40 A at 40 °C. It is a 3-pole device (3P) designed for distribution in 250 A or 400/630 A panelboards. The electronic trip unit provides LSoI protection functions — long-time, short-time, instantaneous, and earth-leakage (though earth-leakage protection is not fitted on this variant).

The utilisation category is Category A, so it is not intended for deliberate short-time delay coordination with downstream devices — selectivity is achieved through the adjustable short-time pickup (Isd) set between 1.5 and 10 times the long-time pickup (Ir).

Adjustments and fixed parameters

The long-time pickup (Ir) is adjustable from 18 to 40 A, letting you match the breaker to the actual load without changing the trip unit. The short-time pickup (Isd) is also adjustable, but the long-time delay (tr) and short-time delay (tsd) are fixed — you cannot extend the delay for better selectivity. The instantaneous pickup (Ii) is fixed at 600 A. The breaker mounts on a backplate (panel-mounted) and can be installed horizontally or vertically.

Frequently asked questions

Where can I buy MGP0403XE2 and how is it quoted?

The MGP0403XE2 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm price and lead time.

What is the closest alternative to MGP0403XE2?

There is no official successor order code listed for the MGP0403XE2. The closest alternative would be a parametric match: a PowerPacT 4 or similar panel-mount breaker with a 40 A rating, 3 poles, and an electronic trip unit offering LSoI protection. Confirm the mounting footprint and breaking capacity requirements before substituting.

What is the control type of MGP0403XE2?

The control type is Toggle.

What is the trip unit name on MGP0403XE2?

The trip unit is MicroLogic 2.2.

What compliance documentation does Schneider provide for MGP0403XE2?

The breaker is suitable for isolation conforming to BS EN 60947-2. The evidence does not list RoHS, REACH, UL, or IEC documentation specifically for this order code. Check the Schneider Electric documentation package for the PowerPacT 4 series for full compliance details.